Login

Privacy Policy (GDPR)
Authorization
Not registered yet? Take advantages of registration:
Products saving in a binding to the projects
Product consultation from our experts - Online
Registration
Signup
By using this form, you confirm that you have read the site terms of use Terms of use and completely accept the terms of use

VENTS AOW 30


Air unit with the water heat exchanger. Maximum capacity - up to 3000 m³/h.

  • Description
  • Characteristics
  • Downloads
  • Dimensions
  • ADDITIONAL TECHNICAL DATA
  • Designation key
  • Accessories
Description
Description
APPLICATION CONTROL AND REGULATION
  • Designed for air heating or cooling by water heat medium with subsequent uniform air distribution by the fan and louvre shutters.
  • The AOW1 unit is designed for air heating only.
  • The units provide quick heating or cooling of large premises due to high efficient air heater and powerful fan and are suitable for local air heating or cooling of working areas in hangars or large industrial premises.
  • Further application areas include workshops, garages, car showrooms, stock houses, trade facilities, super- and hypermarkets, shops, sport halls, conference halls, poultry and cattle farms, greenhouses and other similar premises.
  • The unit design enables quick and easy mounting and reduces total investment costs for heating (cooling) system.
  • Both smooth or step speed control with a thyristor or autotransformer controller.
  • Motor speed decrease allows reducing flow and value of heating or cooling energy transfer.
  • The control unit UWT-1E is used for controlling the operation modes of the air heating (cooling) unit (available upon separate order).
  • The control unit has three operation modes, i.e. three modes for speed control of AOW unit.
  • The unit incorporates a switch with a light indicator, cable entry seals for cable connection, safety fuse for short circuit protection.
  • The automation unit is designed for joint operation either with TST-1-300 series digital thermostats with a sensor display (the thermostat TSTD-1-300 is equipped with a remote control panel) or with RTS-1-400 series thermostats with LCD display (RTSD-1-400 is equipped with a remote control panel). The digital thermostats are available upon separate order.
  • Install the thermostat in the same room where the AOW /AOW1 unit is installed. It is used to measure the indoor temperature and control the unit operation.
  • For correct functioning of the unit install the thermostat in places that are not subjected to temperature fluctuations, i.e. close to windows, doors, hot-water radiators.
  • One thermostat can be used for control of several air heating (cooling) units located in the same room.
DESIGN  
  • AOW / AOW1 unit consists of the axial fan and aluminium-copper ribbed water heating coils located in steel casing with polymeric coating.
  • The water coils are equipped with internally threaded pipes on the casig side for connection and supply of heat medium.
  • The units are rated for operation at maximum operating pressure 1.6 Mpa (16 bar) and maximim heat medium temperature 100 °С.
  • The AOW1 unit has a simplified design without a drain pipe and a drain pan.
MOUNTING MOTOR
  • The unit is suitable for vertical installation on walls or columns or horizontal installation on ceiling (beams). See mounting accessories.
  • AC motors with external rotor and built-in thermal overheating protection with automatic restart.
AIR HEATING (COOLING) ADVANTAGES:  
  • quick attaining of the set temperature in the premises,
  • low system response time allows applying varying temperature conditions,
  • high thermal capacity,
  • lower investment costs for air heating (cooling) system as compared to similar water heating (cooling) systems.

VENTS AOW unit greenhouse heating example VENTS AOW unit garage cooling example
VENTS AOW unit stock house heating example
Characteristics
Characteristics
Parameter AOW 30
Measurement unit
Voltage 230 V
Frequency 50 Hz
Fan power 191 W
Fan current 0.85 A
RPM RPM 1440 min-1
Sound pressure level at 3 m Sound pressure level at 3 m 55 dBА
Maximum heat medium temperature Maximum heat medium temperature 100 °С
Protection rating Protection rating IP 44 -
Number of water coil rows Number of water coil rows 2 -
Weight Weight 40 kg
Insulation class B -
Air reach distance Air reach distance 12 mm
Files archieve
Downloads
Select document type
  • Advertising and printing products
  • Certificates
  • Technical documentation
Name
Download high quality image "VENTS AOW (front view)" (psd 2.85Mb)
Download high quality image "VENTS AOW (back view)" (psd 2.56Mb)
"VENTS AOW and AOW1" product description 05-2023 (pdf 1.34Mb)
"Control unit for air heating (cooling) unit with water heat exchanger - UWT series" user's manual 06-2017 (V52-1EN-02) (pdf 383.75Kb)
"VENTS AOW" user's manual 11-2019 (V52EN-05) (pdf 1.67Mb)
Download high quality image "VENTS AOW1" (psd 2.25Mb)
Download image "VENTS AOW1" for your website (png 432.52Kb)
Download image "VENTS AOW (front view)" for your website (png 606.89Kb)
Download image "VENTS AOW (back view)" for your website (png 697.72Kb)
Dimensions
Characteristics
VENTS AOW 30
Parameter Value Measurement unit
B 680 mm
B1 785 mm
H 655 mm
H1 518 mm
L 360 mm
L1 286 mm
K G 3/4'' mm
ADDITIONAL TECHNICAL DATA
ADDITIONAL TECHNICAL DATA

TECHNICAL DATA FOR HEATING MODE

Model Air flow [m3/h] Inlet air temp. [°С] Temperature difference 90/70 °С Temperature difference 80/60 °С Temperature difference 70/50 °С Temperature difference 60/40 °С
Power [kW] Outlet air temp. [°С] Water flow [m3/h] Water pressure loss [kPa] Power [kW] Outlet air temp. [°С] Water flow [m3/h] Water pressure loss [kPa] Power [kW] Outlet air temp. [°С] Water flow [m3/h] Water pressure loss [kPa] Power [kW] Outlet air temp. [°С] Water flow [m3/h] Water pressure loss [kPa]
AOW 30 3000 -15 48.4 27.2 2.09 7.4 42.0 22.0 1.91 6.0 36.6 17.0 1.58 4.7 31.0 11.7 1.30 3.5
-10 45.4 30.3 2.02 6.6 39.0 25.2 1.69 5.3 33.7 20.0 1.51 4.0 27.6 14.6 1.19 2.9
-5 42.4 33.4 1.91 5.9 36.7 28.2 1.58 4.6 30.0 22.9 1.40 3.4 24.0 17.4 1.12 2.4
0 39.5 36.4 1.69 5.2 33.8 31.1 1.51 3.9 28.0 25.7 1.19 2.9 21.0 20.0 1.01 1.9
5 36.7 39.4 1.58 4.5 30.9 34.0 1.40 3.4 25.0 28.5 1.12 2.4 19.0 22.7 0.79 1.5
10 33.8 42.1 1.51 3.9 28.1 36.7 1.19 2.8 22.0 31.1 1.01 1.9 16.0 25.2 0.68 1.1
15 31.0 44.9 1.40 3.3 25.3 40.0 1.12 2.3 19.4 33.7 0.90 1.5 13.0 27.5 0.61 0.7

TECHNICAL DATA FOR COOLING MODE

Model Air flow [m3/h] Inlet air temp. [°С] Temperature difference 7/12 °С
Power [kW] Outlet air temp. [°С] Water flow [m3/h] Water pressure loss [kPa]
AOW 30 3000 35 11.4 27.0 2.0 11.2
30 7.3 22.9 1.3 5.0
25 3.9 21.1 0.7 1.6
20 2.4 17.7 0.4 0.7
Designation key
Designation key
Series Rated power [kW]
VENTS AOW
VENTS AOW1
25; 30; 45
Accessories
Accessories
Air heating unit model Control unit Digital thermostat Mounting accessories
with sensor display with LCD display Mounting angles Mounting brackets
AOW 25 UWT-1E TST-1-300
TSTD-1-300
RTS-1-400
RTSD-1-400
MKP-AOW MK-AOW 25
AOW1 25 MK-AOW1 25
AOW 30 MK-AOW 30
AOW1 30 MK-AOW 25*
AOW 45 MK-AOW 45
AOW1 45 MK-AOW 30*

* The cross pieces between the MK-AOW mounting brackets are not applicable in case of AOW1 mounting.

Share your opinion

Questionnaire
Where have you learned about us?