VENTS DVUT 500 PBE EC V.2


Suspension-mounted single-room air handling unit with air flow up to 510 m³/h in a heat- and sound-insulated casing. Heat recovery efficiency up to 96 %.

  • Description
  • Characteristics
  • Downloads
  • Dimensions
  • Additional characteristics
  • Designation key
  • Accessories
Description
Description
DESCRIPTION  
  • The DVUT PB EC V.2 air handling units are intended for single-room ventilation of schools, offices and other public and commercial spaces.
  • The air handling units do not require a duct system and provide a simple yet efficient ventilation solution for newly built and renovated spaces.
FEATURES  
  • Efficient supply and exhaust ventilation of individual spaces.
  • Modification with an electric preheater or reheater available.
  • Low-energy EC motors.
  • Very quiet operation.
  • Supply and extract air purification by means of in-built filters.
  • Simple installation.
  • Contemporary design.
OPERATING PRINCIPLE
  • Warm, stale air passes through the filter and the heat exchanger and is then extracted outdoors through the wall duct by the centrifugal extract fan. Cold outdoor air passes through the filters and the heat exchanger and is then supplied by means of the centrifugal supply fan. This air is warmed up in the heat exchanger, providing fresh air supply into a premise and maintaining comfortable temperature.
CASING
  • The casing is made from high-quality polymer-coated steel with internal heat and sound insulation made of mineral wool 30 mm in thickness. The contemporary design helps the units blend in nicely with a wide variety of interiors.
AIR DAMPERS
  • Supply and exhaust dampers are closed automatically while the unit is off to prevent drafts.
AIR FILTRATION
  • Supply and extract air is purified by means of panel filters. The filtering class depends on standard sizes.

FANS
  • The units feature high-performance, electronically commutated (EC) external rotor motors with forward curved blades. These state-of-the-art units offer excellent energy efficiency. In addition to that, EC motors combine high performance and optimum control over the entire speed range. EC motors have an excellent power efficiency (up to 90 %).
PREHEATING
  • The DVUT PBE EC V.2 and DVUT PBE2 EC V.2 units are equipped with an electric preheater to prevent heat exchanger freezing.
REHEATING
  • The DVUT PBE2 EC V.2 units are equipped with electric reheaters to raise the supply air temperature.
BYPASS
  • The units are equipped with a bypass for summer ventilation.
 
HEAT EXCHANGER  
  • The DVUT unit features a counter-flow heat exchanger made of polystyrene. In the cold season the heat from the extract air is transferred to the supply air via the heat exchanger which greatly helps reduce ventilation heat losses. This can lead to formation of condensate that is collected in a special drain pan and discharged into the sewage system. In the warm season the outdoor air heat is transferred to extract air. This enables considerable reduction of the supply air temperature which reduces the air conditioning load.
UNIT CONTROL AND AUTOMATION  

Freeze protection

  • There are two methods of protecting the heat exchanger against freezing in cold conditions. In units without an electric preheater the supply fan is shut down automatically, using the feedback from the extract air temperature sensor, to let the warm extract air thaw the heat exchanger. The supply fan then re-activates and the unit reverts to normal operation. In units with an electric preheater the supply air is warmed up before entering the heat exchanger which prevents freezing. This method ensures a continuous, balanced air exchange.

Control

  • The units DVUT PB EC V.2 A21 are equipped with an in-built control system. An A21 controller allows integrating the unit into the Smart Home system or BMS (Building Management Systems). Remote control panel is not included in the delivery set and is available as specially ordered accessory. The unit is controlled via Wi-Fi by means of the Vents Home mobile application that must be downloaded.
   
Function А21
Wired remote control panel Option (А22)
Wired remote sensor control panel Option (А25)
Wireless remote control panel Option (А22 Wi-Fi)
BMS RS-485
Wi-Fi
Ethernet
MODBUS (RTU, TCP)
Control by a mobile application via Wi-Fi +
Freeze protection +
Bypass Auto + manual
Weekly schedule operation +
Filter maintenance warning According to filter timer
According to pressure switch of filter clogging
Alarm indication +
Speed selection +
Timer +
RH% sensor Option
COsensor Option
VOC sensor Option
PM2.5 sensor Option
Boost mode +
Fireplace mode +
Preheating Option
Reheating Option
Cooler connection Option
Fire alarm sensor Option
Supply air temperature control +
Characteristics
Characteristics
Parameter DVUT 500 PBE EC V.2
Measurement unit
Phase 1 ˜
Voltage 230 V
Maximum unit current 1.7 A
Frequency 50/60 Hz
Electric preheater power 1050 W
Air capacity 510 m³/h
Max. unit current with electric heater 9.3 A
Max. unit power without electric heater 238 W
Heat recovery efficiency 83-96 %
Transported air temperature -25 ... +40 °С
Sound pressure level at 1 m distance 44 dBА
Sound pressure level at 3 m distance 34 dBА
Connected air duct diameter Connected air duct diameter 250 mm
Functions Wi-Fi, Filter replacement indication, Timer, Weekly schedule, External sensor connection -
Heating electric preheating -
Casing material polymer coated steel -
Insulation 25 mm, EPDM (polyurethane foam) -
Filter: extract ISO Coarse >60% (G4) -
Filter: supply ISO ePM1 60% (F7) -
Weight 95 kg
Heat exchanger type counter-flow -
Heat exchanger material polystyrene -
SEC Class A+ -
Mounting ceiling mounting -
Files archieve
Downloads
Select document type
  • Advertising and printing products
  • Certificates
  • Technical documentation
Name
"DVUT PB EC V.2" user's manual 04-2023 (V177EN-06) (pdf 4.24Mb)
"DVUT 1000 PB EC V.2" user's manual 03-2023 (V177-1EN-03) (pdf 5.98Mb)
"Wireless control system A21" user’s manual 02-2023 (V55-8EN-05) (pdf 491.75Kb)
Download image "DVUT PB EC V.2" for your website (png 211Kb)
Download high quality image "DVUT PB EC V.2" (psd 1009.05Kb)
"Single-room ventilation for schools and public spaces" catalog 2023 (pdf 4.68Mb)
"BMS parameter table for PCOS004850 module for DVUT units" user’s manual 07-2020 (V197-1EN-02) (pdf 71.29Kb)
Dimensions
Characteristics
VENTS DVUT 500 PBE EC V.2
Parameter Value Measurement unit
D 250 mm
A 1500 mm
A1 1135 mm
A2 186 mm
A3 1422 mm
B 850 mm
B1 181 mm
B2 530 mm
B3 207 mm
H 458 mm
H1 221 mm
N 504 mm
M 41 mm
Additional characteristics
Additional characteristics


Point Power [W] Sound pressure level at 3 m (1m) [dBA]
1 170 34 (44)
2 153 -
3 135 34 (44)
4 116 35 (44)
5 95 28 (37)
6 86 -
7 80 -
8 68 -
9 25 17 (26)
10 24 -
11 24 -
12 22 -

 


Fresh air stream length
Sound power level,
A-weighted
Total Octave frequency band [Hz] LpA, 3 m LpA, 1 m 
200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000 6300 8000 10000
LwA to environment at point 1 [dBA] 54.7 44.7 48.8 46.3 45.7 41.3  38.8 40.9 40.4 40.2 42.8 43.0 40.0 32.8 27.7 25.7 23.6 25.9 25.8 43.7 34.1
LwA to environment at point 5 [dBA] 48.2 44.7 37.8 37.3 38.6 32.7 31.5 32.8 33.0 32.8 35.3 35.1 31.2 23.8 20.7 20.2 19.8 23.2 24.2 37.2 27.7
LwA to environment at point 9 [dBA] 33.6 22.9 21.9 27.0 24.3 17.8 17.1 17.6 16.9 16.4 17.2 17.6 17.1 17.5 17.8 18.7 19.5 23.0 24.1 22.6 13.0
LwA to environment at point 3 [dBA] 61.2 55.0 53.5 53.5 52.1 46.5 45.2 46.1 46.1 45.6 46.8 45.9 43.9 39.1 36.4 47.1  40.1 39.9 35.2 50.2 40.7
LwA to environment at point 4 [dBA] 55.4 47.7 47.7 47.2 46.4 42.0 39.4 40.7 41.3 41.2 43.8 44.0 41.5 33.8 29.0 26.8 23.9 25.2 24.9 44.4 34.8
Designation key
Designation key
Unit series Rated air flow [m³/h] Installation Bypass Electric heaters Drain pump Motor type Modernization Control
DVUT – unit with plastic heat exchanger 300
500
1000
P – suspended with horizontal spigots

P1 – suspended with vertical spigots
B – bypass damper _ – no heater

E – electric preheater

E2 – electric preheater and reheater
_ – without drain pump

DN – in-built drain pump
ЕС – synchronous motor with electronic control V.2 – second modernized generation А21
Accessories
Accessories
Name Image DVUT 300 PB/PBE/PBE2 EC V.2 DVUT 500 PB/PBE/PBE2 EC V.2 DVUT 1000 PB/PBE/PBE2 EC V.2
External grille MVMA 200 bVn Al MVMA 250 bVn Al MVMA 315 bVn Al
Extract filter
ISO Coarse >60% (G4)
SF 320x373x48 G4 SF 379x334x48 G4 SF 654x480x48 2 pcs.
Supply filter
ISO ePM1 60% (F7)
SF 320x211x48 F7 SF 379x254x48 F7 SF 654x480x48
VOC sensor (0-10 V) DPWQ30600
CO2 sensor (0-10 V) DPWQ40200
Humidity sensor (0-10V) DPWС11200
CO2 sensor CO-1
CO2 sensor CO-2
CO2 sensor CO2-3
Humidity sensor (NO) HR-S
Humidity sensor HV2
Hydraulic U-trap SG-32
Drain pump DN-2
Vertical duct connection module MVC DVUT 1000
Share your opinion

Questionnaire
How often do you use equipment selection program?