VENTS Enave-CT 100 P A14


Heat recovery air handling unit in sound- and heat-insulated casing. Air flow up to 130 m³/h. Heat recovery efficiency up to 88 %.

  • Description
  • Characteristics
  • Downloads
  • Dimensions
  • Additional characteristics
  • Designation key
  • Accessories
Description
Description
DESCRIPTION AUTOMATION
  • The air handling units are the fully featured ventilation units with heat recovery for air filtration, fresh air supply and stale air extract.
  • The units offer energy-efficient ventilation for small appartments.
  • Enave-C 100 P A14 units are equipped with an integrated control system and an A14 wall-mounted control panel with LED indication.
CASING FREEZE PROTECTION
  • The casing is made of expanded polypropylene (EPP) possessing high heat- and sound-insulating properties.
  • In the Enave-C 100 P A14 units freeze protection is provided by the shutdown of the supply fan.
FILTER MOUNTING
  • Two built-in G4 and F7 filters provide efficient air filtration.

  • The unit is designed for suspended ceilling mounting.
  • The mounting position of the unit must provide service access for maintenance and repair.
FANS CONTROL AND AUTOMATION
  • Efficient electronically commutated motors with external rotor and impeller with forward curved blades.
Functions A14
Control via external wired control panel
А14
Speed selection +
Filter replacement indication According to filter timer
Alarm indication Alarm LED indication
Freeze protection Cyclic shutdown of supply fan
Humidity control Option
CO2 control Option
Fire alarm connection Option
  
HEAT EXCHANGER
  • Enave-C units are equipped with a counter-flow polystyrene heat exchanger.

  • Enave-CT units are equipped with an enthalpy heat exchanger.

Characteristics
Characteristics
Parameter Enave-CT 100 P A14
Measurement unit
Frequency 50/60 Hz
Phase 1 ˜
Voltage 230 V
Maximum unit power 38 W
Maximum unit current 0.34 A
Air capacity 130 m³/h
Heat recovery efficiency 73-88 %
Transported air temperature - 23...+40 °С
Sound pressure level at 3 m distance 32 dBА
Casing material expanded polypropylene -
Insulation 25 mm -
Filter: extract G4 / Coarse > 60% -
Filter: supply G4 / Coarse > 60% (option F7 / ePM1 60%) -
Connected air duct size 100 / 125 mm
Weight 8 kg
Heat exchanger type counter-flow -
Heat exchanger material enthalpy -
SEC Class A -
Files archieve
Downloads
Select document type
  • Advertising and printing products
  • Certificates
  • Technical documentation
Name
Software "Setting air handling units with automation A14 and A15" (rar 17.47Mb)
"Sensor control panel A14/A15" user’s manual 04-2019 (V55-7EN-02) (pdf 1.16Mb)
"VENTS Enave-C 100 P A14" product description 08-2023 (pdf 953.94Kb)
Download high quality image "VENTS Enave-C 100 P A14" (psd 2.77Mb)
Download image "VENTS Enave-C 100 P A14" for your website (png 806.65Kb)
"VENTS Enave-C 100 P A14" user’s manual 08-2023 (V224EN-01) (pdf 3.03Mb)
Dimensions
Characteristics
VENTS Enave-CT 100 P A14
Parameter Value Measurement unit
∅D 125 mm
∅d 104 mm
H 247 mm
W 522 mm
L 530 mm
B 630 mm
W1 600 mm
Additional characteristics
Additional characteristics
Point Air flow [m3h] (ls) Total sound pressure level (breakout)
at 3 m (1 m) distance [dBA]
Enave-CT 100 P Enave-CT 100 P
1 130 (36) 32 (42)
2 91 (25) 25 (35)
3 52 (14) 16 (26)
4 52 (14) 31 (41)
5 96 (27) 33 (42)
6 68 (19) 25 (34)

  

A-weighted sound power level
(p.5 on the diagram)
Gen. Octave-frequency band [Hz] LpA, 3 m [dBA] LpA, 1 m [dBA]
dBA 200 400 800 1000 2000 4000 8000    
LwA to exhaust inlet dBA 59 44 45 49 51 44 37 38 38 48
LwA to supply outlet dBA 47 41 36 33 31 29 22 24 27 36
LwA to environment dBA 53 37 41 43 42 38 34 29 33 42

Calculation of air temperature downstream of the heat exchanger:

t = toutd + khr * (textr - toutd) / 100,

where
toutd is outdoor air temperature [°C]
textr is extract air temperature [°С]
khr is heat exchanger efficiency (according to the diagram) [%]

Designation key
Designation key
TM Model Casing modification Heat exchanger type Nominal size Modification Casing type Heater Controller Service side
VENTS Enave С – Compact _ – heat recovery
T – energy recovery
Air flow m3/h / 10 0 – standard P – suspended _ – w/o heater А14 _ – universal
Accessories
Accessories
Model G4 panel filter F7 panel filter Internal humidity sensor CO2 sensor with indication CO2 sensor Humidity sensor U-trap kit Air damper Electric actuator
Enave-C 100 P A14 SF 176x150x22 G4 SF 176x150x22 F7 HV2 CO2-1 CO2-2 HR-S SG-32 KRV 125 LF230
Enave-CT 100 P A14