Login

Privacy Policy (GDPR)
Authorization
Not registered yet? Take advantages of registration:
Products saving in a binding to the projects
Product consultation from our experts - Online
Registration
Signup
By using this form, you confirm that you have read the site terms of use Terms of use and completely accept the terms of use

VENTS MPA 800 W


Supply unit with the air flow up to 750 m³/h in the compact sound- and heat-insulated casing with water heater

  • Description
  • Characteristics
  • Downloads
  • Dimensions
  • Additional characteristics
  • Hot water coil parameters
  • Designation key
  • Accessories
Description
Description
DESCRIPTION CASING
  • Air supply MPA unit is a complete ventilation unit for air filtration, air heating and supply to premises.
  • Steel casing covered with aluzinc coating internally filled with 25 mm heat- and sound-insulating layer made of mineral wool.
FILTER HEATER
  • Integrated panel G4 filter ensures sufficient supply air purification.
  • Water/glycol heaters are used for heating of supply air in cold season.
  • The water heaters are designed for max. operating pressure 1.0 MPa (10 bar) and max. operating temperature 95 °C of the heat medium.
FAN CONTROL AND AUTOMATION
  • Centrifugal double-inlet fan with forward curved blades and built-in overheating protection with automatic restart.
  • The ball bearings in the electric motor are maintenance free and designed for at least 40,000 hours operation.
  • Integrated control and automation system for threespeed (air flow) control and setting supply air temperature.
  • The unit may be controlled from the external control panel fixed on 10 m wire delivered as a standard.
MPA...W CONTROL AND PROTECTION FUNCTIONS  
  • Switching the unit motor on/off.
  • Three-speed fan selection.
  • Maintaining set supply air temperature by means of controlling the circulating pump and heat medium regulating valve.
  • Water heater freezing protection by the temperature sensor at outlet from the heating coils and the return heat medium temperature sensor.
  • Control and regulation of the external circulation pump installed at the heat medium supply line to the water heater (mixing unit pump).
  • Control of the compressor and condensing unit of the water cooler by the room temperature sensor (for the models equipped with a duct air cooler).
  • Supply fan control and regulation.
  • Filter clogging control.
  • Actuating the external air damper with a return spring.
  • Unit shut down at signal from the fire alarm system.
  • The mixing units USWK are recommended for smooth supply air temperature regulation in the units equipped with water heaters.
  • The mixing unit USWK with three-way heat medium regulating valve and circulation pump provides smooth heating capacity regulation and minimizes the water heater freezing danger.
MOUNTING  
  • The supply unit can be mounted on the floor, suspended to the ceiling by means of a seat angle with a flexible connector or fixed to the wall using brackets.
  • The unit can be installed either in such service spaces as balcony, storeroom, basement, roof space or in main premises above the suspended ceiling, in the pocket or placed directly in the room.
  • The unit can be mounted in any position but the vertical one with air downstream because the heating elements are not allowed under the fan.
  • Access for the unit maintenance and filter cleaning shall be provided.
OFFICE VENTILATION EXAMPLE  
  • Air supply and exhaust ventilation in the modern office can be arranged as follows.
  • Air handing MPA unit, exhaust fan complying with MPA unit characteristics, intake and exhaust main air ducts are mounted in the hall behind the suspended ceiling.
  • The branchings are laid into the office premises and air distribution units. Intake air from outside flows through the external grille, is filtered in the air handling unit, heated to the required temperature and supplied to the office rooms through the branch duct system.
  • Exhaust air is extracted outside through the external grille by means of the exhaust fan.
  • Thus the office has the permanent fresh air supply, controllable air exchange, no draughts when opened windows, no dust and no noise.
MPA unit office air exchange example
Characteristics
Characteristics
Parameter MPA 800 W
Measurement unit
Frequency 50 Hz
Phase 1 ˜
Voltage 230 V
Maximum fan power 245 W
Fan current 1.08 A
Total unit power 245 W
Total unit current 1.08 A
Air capacity 750 m³/h
Number of water (glycol) coil rows 4 -
RPM 1650 min-1
Noise level at 3 m 35 dBА
Maximum transported air temperature -25 ... +40 °С
Casing material aluzinc -
Filter G4 -
Insulation 25 mm mineral wool -
Connected air duct size 400х200 mm
Weight 41.3 kg
Outdoor mounting no -
Duct for rectangular air ducts -
Type supply -
Mounting floor mounting, wall mounting, ceiling mounting -
Files archieve
Downloads
Select document type
  • Advertising and printing products
  • Certificates
  • Technical documentation
Name
"VENTS MPA...E, MPA...W" product description 01-2023 (pdf 5.26Mb)
Download high quality image "VENTS MPA...W (ErP 2016, 2018)" (psd 4.28Mb)
"Control system for air supply and air handling units based on Freemax controllers and AC208A2 sensor control panels" user's manual 07-2023 (V99EN-03) (pdf 7.14Mb)
"VENTS MPA...W" user's manual 07-2015 (V38EN-02) (pdf 3.03Mb)
Download image "VENTS MPA...W (ErP 2016, 2018)" for your website (png 496.06Kb)
Dimensions
Characteristics
VENTS MPA 800 W
Parameter Value Measurement unit
B 400 mm
B1 420 mm
B2 549 mm
B3 500 mm
H 200 mm
H1 220 mm
H2 352 mm
L 650 mm
L1 530 mm
L2 mm
Additional characteristics
Additional characteristics
Sound-power level Octave-frequency band [Hz]
  Hz Gen 63 125 250 500 1000 2000 4000 8000
LwA to inlet dBA 62 64 62 60 62 54 56 50 44
LwA to outlet dBA 61 67 65 63 59 59 55 52 45
LwA to environment dBA 38 45 55 42 36 34 26 24 21
Hot water coil parameters
Hot water coil parameters

How to use water heater diagrams

System Parameters: Air flow = 950 m³/h. Outside air temperature = -15 °C. Water temperature (in/out) = 70/50 °C.

  • Air Speed. Starting from 950 m³/h on the air flow scale draw a vertical line till the air speed axis which makes about 3.35 m/s.
  • Supply air temperature. Prolong the line up to the point where it crosses the outside air temperature (blue curve), e.g. -15 °C; then draw a horizontal line from this point to the left till crossing water in/out temperature curve (70/50 °C). From this point draw a vertical line to the supply air temperature axis on top of the graphic (+29 °C).
  • Heating coil capacity. Prolong the line up to the point where it crosses the outside air temperature -15 °C (red curve) and draw a horizontal line from this point to the right until it crosses water in/out temperature curve (70/50 °C), from here draw a vertical line up to the scale representing the heating coil capacity (16 kW).
  • Water flow. Prolong the line down to water flow axis at the bottom of the graphic (0.2 l/s).
  • Water pressure drop. Draw the line from the point where line crosses the black curve to the pressure drop axis. (2.1 kPa).
Designation key
Designation key
Series Rated air flow, m³/h Heater type Integrated control system
VENTS MPA 800; 1200; 1800; 2500; 3200; 3500; 5000 W: water LCD: integrated automation with A16 control panel
Accessories
Accessories
Type Replaceable filter Filter type
MPA 800 W SF 442x275x47 G4 panel filter
MPA 1200 W
MPA 1800 W SF 390x545x47 G4 panel filter
MPA 2500 W
MPA 3200 W SF 653x440x47 G4 panel filter
MPA 3500 W
MPA 5000 W SFK 868x573x27 G4 pocket filter
Share your opinion

Questionnaire
How often do you use equipment selection program?