VENTS PA 03 E


Suspended air supply unit with the air flow up to 3350 m³/h in the sound- and heat-insulated casing with the electric heater

  • Description
  • Characteristics
  • Capacity diagram
  • Downloads
  • Dimensions
  • Additional characteristics
  • Designation key
  • Accessories
Description
Description
DESCRIPTION CASING
  • The PA unit is a ready to use ventilation unit for air filtration, warming and supply to the room.
  • Steel casing covered with aluzinc coating internally filled with 50 mm heat- and sound-insulating layer made of mineral wool.
FILTER HEATER
  • Integrated panel G4 filter ensures sufficient supply air purification (optionally F7).
  • The PA units are equipped with electric heater.
FAN  
  • The unit is equipped with a direct-driven centrifugal fan with backward curved blades and external rotor motor.
  • The fan configuration ensures the best operating characteristics: high air flow and efficiency combined with low noise level.
MOUNTING  
  • The unit is designed for indoor installation either on the floor, on the wall or under the ceiling by means of a seat angle with inserted vibration-damping element or attached to a wall with brackets.
  • The unit can be mounted either in service spaces or in main premises above the suspended ceiling, in the pocket or the unit can be placed directly in the room.
  • All the electrical connections are performed through the terminal box placed in the connection box.
  • PA supply units are supplied with the fastening brackets to facilitate mounting.
  • The unit can be mounted in any position but the vertical one with vertical air downstream because the electrical heating elements are not allowed under the fan.
  • Access for the unit maintenance and filter cleaning shall be provided.
CONTROL AND AUTOMATION  
  • Integrated control and automation system for speed (air flow) control and setting supply air temperature.
  • The unit may be remotely controlled from the external control panel fixed on wire.
CONTROL AND PROTECTION FUNCTIONS  
  • control from the control panel: switching the unit on/off, fan speed selection (low/medium/high speed), selecting heating/cooling modes (if connected to duct heater);
  • maintaining supply air temperature set from the control panel by smooth heating capacity control;
  • smooth frequency speed control of the fan;
  • safe start-up/shutdown of the fans;
  • Active overheating protection of the electric heating elements by the temperature sensor and by the thermostats activated at 60 °C with automatic reset and at 90 °C with manual reset. Blowing of the electric heating elements for heat removal at the end of the heating cycle.
  • Filter clogging control with differential pressure sensor.
  • Actuating the external air damper.
  • Input from the fire alarm system.
  • Control of the compressor and condensing block of the water cooler by the room temperature sensor (for models with external duct air cooler).
  • Maintaining of set supply air temperature set from the control panel by smooth heating capacity control;
  • smooth frequency fan speed control.
Characteristics
Characteristics
Parameter PA 03 E
Measurement unit
Frequency 50 Hz
Phase 3 ˜
Voltage 400 V
Maximum fan power 1330 W
Fan current 2.4 A
Electric heater power 21000 W
Electric heater current 30 A
Air capacity 3350 m³/h
Total unit power 22330 W
Total unit current 32.4 A
RPM 2730 min-1
Filter panel filter G4 -
Transported air temperature -25 ... +40 °С
Sound pressure level at 3 m distance 57 dBА
Casing material aluzinc -
Heating electric heating -
Insulation 50 mm mineral wool -
Connected air duct size 600х350 mm
Width 600 mm
Weight 91 kg
Height 350 mm
Duct for rectangular air ducts -
Capacity diagram
Capacity diagram
  • Selection method:
  • Air flow:
  • Pressure:
Operating point
  • Air flow: --
  • Pressure: ---
Files archieve
Downloads
Select document type
  • Advertising and printing products
  • Certificates
  • Technical documentation
Name
"VENTS PA...E, PA...W" product description 01-2023 (pdf 5.09Mb)
Download high quality image "VENTS PA...E (ErP 2016, 2018)" (psd 3.74Mb)
"VENTS PA...E. Unit without automation block" user's manual 06-2012 (V53EN-02) (pdf 570.18Kb)
"Control system for air supply and air handling units based on Freemax controllers and AC208A2 sensor control panels" user's manual 07-2023 (V99EN-03) (pdf 7.14Mb)
Download image "VENTS PA...E (ErP 2016, 2018)" for your website (png 229.93Kb)
Dimensions
Characteristics
VENTS PA 03 E
Parameter Value Measurement unit
B 600 mm
B1 620 mm
B2 888 mm
B3 744 mm
H 350 mm
H1 370 mm
H2 500 mm
L 1252 mm
L1 1212 mm
Additional characteristics
Additional characteristics
Sound-power level Gen Octave-frequency band [Hz]
63 125 250 500 1000 2000 4000 8000
LWA to inlet dBA 72 58 71 67 59 49 51 56 54
LWA to outlet dBA 77 58 71 73 71 70 68 65 55
LWA to environment dBA 58 41 59 62 51 47 53 51 46
Designation key
Designation key
Series Unit standard size Heater type Integrated control system
VENTS PA  01; 02; 03; 04 Е: electric LCD: integrated automation with A16 control panel  
Accessories
Accessories
Type G4 replaceable filter Filter type
PА 01 Е SF 475x270x48 G4 panel filter
PА 02 Е SF 540x340x48 G4 panel filter
PА 03 Е SF 635x395x48 G4 panel filter
Share your opinion