VENTS TT PRO 100
Inline mixed flow fan. Maximum capacity - 245 m3/h.
3D model
Gallery
- Description
- Characteristics
- Capacity diagram
- Downloads
- Dimensions
- Additional characteristics
- Designation key
- BIM
Description
Description
APPLICATION | |
|
|
DESIGN | |
|
|
|
|
TT PRO DESIGN FEATURES | |
|
|
MOTOR | |
|
|
SPEED CONTROL | |
|
|
MOUNTING | |
|
|
THE FAN WITH ELECTRONIC MODULE OF THE TEMPERATURE SENSOR AND SPEED CONTROLLER (U OPTION) | |
|
|
OPERATING LOGIC OF THE FAN WITH THE ELECTRONIC MODULE OF THE TEMPERATURE SENSOR AND SPEED CONTROLLER | |
|
|
There are two switch delay patterns for various cases: | |
|
|
TT FANS APPLICATIONS | |
bathroom ventilation example | office ventilation example |
parallel installation of fans in the storehouse to increase the air capacity |
Characteristics
Characteristics
Parameter |
TT PRO 100 min |
TT PRO 100 max |
Measurement unit |
---|---|---|---|
Voltage | 1~230 | 1~230 | V |
Frequency | 60 | 50/60 | Hz |
Sound pressure level at 3 m distance | 27 | 32 | dBА |
Power consumption | 23 | 25 | W |
Maximum air capacity | 180 | 245 | m³/h |
Current | 0.10 | 0.11 | A |
RPM | 2050 | 2620 | min-1 |
Protection rating | IP X4 | IP X4 | - |
Design | mixed-flow | mixed-flow | - |
Weight | 1.75 | 1.75 | kg |
Duct diameter | 100 | 100 | mm |
Casing material | plastic | plastic | - |
SEC Class | C | C | - |
Duct | for round air ducts | for round air ducts | - |
Mounting | Inline | Inline | - |
* | To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). | To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). | - |
Capacity diagram
Capacity diagram
- Selection method:
- Air flow:
- Pressure:
Operating point
- Air flow: --
- Pressure: ---
Files archieve
Downloads
Select document type
Dimensions
Characteristics
Parameter | Value | Measurement unit |
---|---|---|
∅D | 97 | mm |
B | 195.8 | mm |
H | 226 | mm |
L | 302.5 | mm |
Additional characteristics
Additional characteristics
Sound power level, A-filter applied | Sound pressure level at 3 meters, A-filter applied | Sound pressure level at 1 meters, A-filter applied | ||||||||||
Gen. | Octave-frequency band [Hz] | |||||||||||
Hz | 63 | 125 | 250 | 500 | 1000 | 2000 | 4000 | 8000 | LpA, 3 m [dBA] | LpA, 1 m [dBA] | ||
Min speed | ||||||||||||
LwA to inlet | dBA | 54 | 19 | 35 | 50 | 49 | 44 | 37 | 25 | 17 | 33 | 43 |
LwA to outlet | dBA | 53 | 17 | 34 | 50 | 49 | 43 | 36 | 24 | 17 | 32 | 42 |
LwA to environment | dBA | 47 | 14 | 29 | 43 | 43 | 39 | 33 | 22 | 15 | 27 | 37 |
Max speed | ||||||||||||
LwA to inlet | dBA | 59 | 24 | 34 | 53 | 54 | 53 | 48 | 37 | 26 | 38 | 48 |
LwA to outlet | dBA | 57 | 23 | 33 | 52 | 52 | 52 | 47 | 37 | 26 | 37 | 47 |
LwA to environment | dBA | 52 | 18 | 29 | 46 | 48 | 47 | 43 | 33 | 23 | 32 | 42 |
Designation key
Designation key
Series | Air duct diameter | Options |
VENTS TT PRO | 100; 125; 150; 160; 200; 250; 315 | Т: adjustable timer from 2 to 30 minutes; U: speed controller with an electronic thermostat and a temperature sensor integrated inside an air duct. Temperature-based operation logic; Un: speed controller with an electronic thermostat and a temperature sensor fixed on a 4 m cable. Temperature-based operation logic; U1: speed controller with an electronic thermostat and a temperature sensor integrated inside an air duct. Timer-based operation logic; U1n: speed controller with an electronic thermostat and a temperature sensor fixed on a 4 m cable. Timer-based operation logic; U2n: speed controller with an electronic thermostat and a temperature sensor fixed on a 4 m cable. Temperature-based switching on/off; R1: power cord with mains plug; V: threeposition speed switch (for TT PRO series fans only); P: built-in smooth speed controller. |
Accessories