VENTS 120 LD
- Description
- Characteristics
- Capacity diagram
- Downloads
- Modifications
- Dimensions
- Designation key
- Example of installation
Description
Description
APPLICATION | |
|
|
DESIGN | |
|
|
MOTOR | |
|
|
CONTROL | |
Manual:
|
Automatic:
|
MOUNTING FEATURES | |
|
|
MOUNTING EXAMPLE | |
Characteristics
Characteristics
Parameter |
VENTS 120 LD |
VENTS 120 LDT |
VENTS 120 LDTH |
VENTS 120 LDV |
VENTS 120 LDVT |
VENTS 120 LDVTH |
VENTS 120 LD L |
VENTS 120 LD K |
Measurement unit |
---|---|---|---|---|---|---|---|---|---|
Voltage | 220-240 | 220-240 | 220-240 | 220-240 | 220-240 | 220-240 | 220-240 | 220-240 | V |
Frequency | 50 | 50 | 50 | 50 | 50 | 50 | 50 | 50 | Hz |
Power consumption | 16 | 16 | 16 | 16 | 16 | 16 | 16 | 16 | W |
Air capacity | 161 | 161 | 161 | 161 | 161 | 161 | 161 | 161 | m³/h |
Current | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | A |
RPM | 2400 | 2400 | 2400 | 2400 | 2400 | 2400 | 2400 | 2400 | min-1 |
Sound pressure level at 3 m | 34 | 34 | 34 | 34 | 34 | 34 | 34 | 34 | dBА |
Spigot size | 120 | 120 | 120 | 120 | 120 | 120 | 120 | 120 | mm |
Engine Type | 220-240V / 50Hz | 220-240V / 50Hz | 220-240V / 50Hz | 220-240V / 50Hz | 220-240V / 50Hz | 220-240V / 50Hz | 220-240V / 50Hz | 220-240V / 50Hz | - |
Design | axial | axial | axial | axial | axial | axial | axial | axial | - |
Duct diameter | 120 | 120 | 120 | 120 | 120 | 120 | 120 | 120 | mm |
IP Code | IP 34 | IP 34 | IP 34 | IP 34 | IP 34 | IP 34 | IP 34 | IP 34 | - |
Weight | 0.74 | 0.74 | 0.74 | 0.74 | 0.74 | 0.74 | 0.74 | 0.74 | kg |
Type | exhaust | exhaust | exhaust | exhaust | exhaust | exhaust | exhaust | exhaust | - |
Mounting | wall mounting, ceiling mounting | wall mounting, ceiling mounting | wall mounting, ceiling mounting | wall mounting, ceiling mounting | wall mounting, ceiling mounting | wall mounting, ceiling mounting | wall mounting, ceiling mounting | wall mounting, ceiling mounting | - |
Capacity diagram
Capacity diagram
- Selection method:
- Air flow:
- Pressure:
Operating point
- Air flow: --
- Pressure: ---
Files archieve
Downloads
Select document type
Modifications
Modification name |
---|
VENTS 120 LD |
VENTS 120 LDT |
VENTS 120 LDTH |
VENTS 120 LDV |
VENTS 120 LDVT |
VENTS 120 LDVTH |
VENTS 120 LD L |
VENTS 120 LD K |
Modification name | Backdraft damper | Humidity sensor | Timer | Pull-cord switch | Ball bearing motor |
---|---|---|---|---|---|
VENTS 120 LD | - | - | - | - | - |
VENTS 120 LDT | - | - | - | - | |
VENTS 120 LDTH | - | - | - | ||
VENTS 120 LDV | - | - | - | - | |
VENTS 120 LDVT | - | - | - | ||
VENTS 120 LDVTH | - | - | |||
VENTS 120 LD L | - | - | - | - | |
VENTS 120 LD K | - | - | - | - |
|
|
|
|
|
|
|
|
Dimensions
Characteristics
Parameter | Value | Measurement unit |
---|---|---|
Ø D | 120 | mm |
B | 177 | mm |
H | 140 | mm |
L | 129 | mm |
L1 | 34 | mm |
Designation key
Designation key
PICTURE SYMBOL | DESIGNATION | MODIFICATION DESCRIPTION |
LDA | The fan with a ground alumunium front panel. | |
LDA gold | The fan with a gold-tinted aluminium front panel. | |
LDA chrome | The fan with a mirror finish aluminium front panel. | |
LD alumat | The fan with a front panel painted silver (matt). | |
LD alulak | The fan with a front panel painted silver (gloss). | |
LD1 | Shortened branch pipe model. | |
LD K | Fan is equipped with a backdraft damper for back flow preventing. | |
LD L | The motor is equipped with ball bearings for long service life (appr. 40 thousand hours) and fan mounting at any angle. The bearings are maintenance-free and contain enough grease for the entire operating period. | |
LD turbo | High-powered motor. | |
LD 12 | Modification with low-voltage motor. 12 V AC power supply. | |
LDT | Equipped with a regulated timer with the operating time from 2 to 30 minutes. | |
LDTH | Equipped with a timer with the operating time from 2 to 30 minutes and a humidity sensor with the threshold value from 60 to 90 %. | |
LDV | Equipped with a pull cord switch. | |
LDVT | Equipped with a pull cord switch and a regulated timer with the operating time adjustable from 2 to 30 minutes. | |
LDVTH | Equipped with a pull cord switch, regulated timer with the operating time adjustable from 2 to 30 minutes and a humidity sensor with the operating threshold range from 60 to 90 %. |
Example of installation
Example of installation
Accessories
Similar products