Login

Privacy Policy (GDPR)
Authorization
Not registered yet? Take advantages of registration:
Products saving in a binding to the projects
Product consultation from our experts - Online
Registration
Signup
By using this form, you confirm that you have read the site terms of use Terms of use and completely accept the terms of use

VENTS 150 D (127-220 V/60 Hz)

  • Description
  • Characteristics
  • Capacity diagram
  • Downloads
  • Dimensions
  • Wiring plan
  • Legend
  • Example of installation
Description
Description
APPLICATIONS  
  • Continuous or periodic exhaust ventilation of bathroom, showers, kitchens and other utility spaces.
  • Ventilation shaft mounting or duct connection.
  • Low to medium air flow motion for short distances at low air resistance.
  • Compatible with 100, 125 and 150 mm air ducts.
DESIGN  
  • Ultra slim front panel - only 6,5 mm.
  • Modern design and aesthetic look.
  • The casing and the impeller are made of high-quality durable ABS plastic, UV resistant.
  • The intellectual impeller design makes the fan efficiency high and the service life long.
  • Insect screen.
  • Protection rating IP 34.
MOTOR  
  • Reliable and low-watt electric motor.
  • Designed for continuous operation and requires no maintenance.
  • Equipped with overheating protection.
CONTROL  

Manual:

  • The fan is controlled by a room light switch. It is not included in the delivery set.
  • The fan is controlled by the built-in V pull cord switch. Not applied in case of ceiling mounting.
  • Speed control is possible through a thyristor speed controller (see Electrical Accessories). Several fans may be connected to the same controller. Speed controllers can not be connected to the fans with the T, TH, TP, VT, VTH modifications.

Automatic:

  • By the BU-1-60 electronic control unit (see Electrical Accessories). The control unit is supplied separately.
  • By the T timer (the built-in turn-off delay timer enables the fan operation within 2 to 30 minutes after the fan switching off).
  • By the humidity sensor and the TH timer (if the humidity level in the room exceeds the sensor threshold adjustable value within 60-90 %, the fan switches automatically on and operates until the humidity level drops to the standard level, after that the fan continues operating within the time period according to the timer setting, then shuts down).
MOUNTING FEATURES  
  • The fan is mounted directly into the ventilation shaft.
  • In case of remote location of the ventilation shaft flexible air ducts may be used. The air duct is connected to the fan exhaust flange through a clamp.
  • Fixed to the wall by means of screws.
  • Suitable for ceiling mounting.
  • To connect a fan with a 12 V low voltage motor to 220 V/50 Hz power mains, it is necessary to purchase a step-down transformer (e.g. the TRF 220/12-25 transformer).
MOUNTING EXAMPLE  
 
Characteristics
Characteristics
Parameter VENTS 150 D (127-220 V/60 Hz)
127 V
VENTS 150 D (127-220 V/60 Hz)
220 V
Measurement unit
Voltage 127 220 V
Frequency 60 60 Hz
Power consumption 25 25 W
Air capacity 267 267 m³/h
Current 0.175 0.388 A
RPM 2350 2350 min-1
Sound pressure level at 3 m 38 38 dBА
Weight 0.93 0.93 kg
Spigot size 150 150 mm
Design axial axial -
Duct diameter 150 150 mm
IP Code IP 34 IP 34 -
Type exhaust exhaust -
Mounting wall mounting, ceiling mounting wall mounting, ceiling mounting -
Capacity diagram
Capacity diagram
  • Selection method:
  • Air flow:
  • Pressure:
Operating point
  • Air flow: --
  • Pressure: ---
Files archieve
Downloads
Select document type
  • Advertising and printing products
  • Certificates
  • Technical documentation
Name
"VENTS D" product description 09-2018 (pdf 3.53Mb)
Declaration of сonformity "D,S (12V)" (pdf 1.74Mb)
Download high quality image "VENTS D" (psd 2.67Mb)
Declaration of сonformity "D,D L" (pdf 1.65Mb)
"VENTS domestic fans" user's manual 07-2023 (V01EN_16-01) (pdf 3.9Mb)
Download image "VENTS D" for your website (png 644.84Kb)
Certificate GS "K,K1,PF,М,D,S,LD,М1,+L" (pdf 124.5Kb)
Certificate LVD "K,K1,PF,М,D,S,LD,М1,MA+turbo (12V)" (pdf 473.42Kb)
"VENTS D, D1" user’s manual 04-2023 (V220EN-02) (pdf 1.87Mb)
"VENTS D, D1 (120 V / 60 Hz)" user’s manual 04-2023 (V12060_220EN-02) (pdf 1.87Mb)
"VENTS D (127-220 V / 60 Hz)" user’s manual 05-2022 (V202-1EN-02) (pdf 1.43Mb)
Dimensions
Characteristics
VENTS 150 D (127-220 V/60 Hz)
Parameter Value Measurement unit
∅D 150 mm
B 205 mm
H 165 mm
L 132 mm
L1 13 mm
Wiring plan
Wiring plan
Wiring diagram for the fans equipped with a built-in switch Wiring diagram for the fans without built-in switch
Wiring diagram for the fans equipped with a timer / timer, humidity sensor and a built-in switch Wiring diagram for the fans equipped with a timer / timer with a humidity sensor without built-in switch
Wiring diagram for the fans with a light lamp. Separate activation of the fan and the built-in lamp. Wiring diagram for the fans with a light lamp. Parallel activation of the fan and the built-in lamp.
Wiring diagram for the fans with an light lamp and grounding. Separate activation of the fan and the built-in lamp. Wiring diagram for the fans with a light lamp and grounding. Parallel switching of the fan and the built-in lamp.
Wiring diagram for the fans with grounding  
 

* - only for fans designed for 12 V rated voltage (specified on the fan casing and packing).
S, S1, S2 - external switches.

Operating logic of the fans with optional equipment
  • The fan equipped with a timer is activated by the control voltage supplied to LT input. After the control voltage is disconnected the fan continues operating within the time period within 2 to 30 minutes according to the timer settings. The turn-off delay time is adjusted by turning the respective potentiometer T control knob clockwise to increase and counter-clockwise to reduce it.
  • The fan equipped with a timer and humidity sensor is activated by the control voltage supplied to LT input or in case of exceeding the preset humidity threshold value adjustable from ~60% to ~90%. After the control voltage is disconnected or as the humidity level H drops below the set threshold the fan continues operating within the time period within 2 to 30 minutes according to the timer settings.  The turn-off delay time and the threshold humidity level are adjusted by turning the control knob of the respective potentiometer T for timer and H for humidity sensor clockwise to increase and counter-clockwise to reduce the set value. To set the maximum humidity level (90%) set the potentiometer control knob for H max position.
  • The fan equipped with a timer and motion sensor is activated in case of the moving detection at the distance from 1 m to 4 m with 100° detection angle. After motion is off the fan continues operating within the time period within 2 to 30 minutes according to the timer settings. The turn-off delay time is adjusted by turning the respective potentiometer T control knob clockwise to increase and counter-clockwise to reduce it.
  • Wiring diagram for connection of the light lamp to the fan timer operated by the common switch is shown on diagram 4. Upon the light lamp disconnection the fan continues operating according to the timer setting within the set time period.
Legend
Legend
PICTURE SYMBOL DESIGNATION MODIFICATION DESCRIPTION
  D1 Shortened flange model.
D К Fan is equipped with a backdraft damper for back flow preventing.
D L The motor is equipped with ball bearings for long service life (appr. 40 thousand hours) and fan mounting at any angle. The bearings are maintenance-free and contain enough grease for the entire operating period.
D turbo High-powered motor.
D 12 Modification with low-voltage motor. 12 V AC power supply.
DT Equipped with a regulated timer with the operating time from 2 to 30 minutes.
DTH Equipped with a timer with the operating time from 2 to 30 minutes and a humidity sensor with the threshold value from 60 to 90%.
DV Equipped with a pull cord switch.
D Equipped with a pull cord switch and a regulated timer with the operating time adjustable from 2 to 30 minutes.
DVТН Equipped with a pull cord switch, regulated timer with the operating time adjustable from 2 to 30 minutes and a humidity sensor with the operating threshold range from 60% to 90%.
Example of installation
Example of installation

Accessories Similar products
Share your opinion

Questionnaire
Where have you learned about us?