VENTS VUE 230 V5 А3/A4
Heat recovery air handling units in sound- and heat-insulated casings. Air flow up to 230 m³/h. Heat recovery efficiency up to 98 %.
- Description
- Characteristics
- Capacity diagram
- Downloads
- Dimensions
- Additional technical data
- Designation key
- Accessories
- Video
Description
Description
DESCRIPTION | |
|
|
FILTER | CASING |
|
|
FILTER | |
|
|
HEAT EXCHANGER | |
|
|
CONTROL AND AUTOMATION | |
|
|
FREEZE PROTECTION | INSTALLATION |
|
|
UNIT DESIGN | |
APPLICATION OPTIONS | |
Characteristics
Characteristics
Parameter |
VENTS VUE 230 V5 A3/A4 |
Measurement unit |
---|---|---|
Frequency | 50/60 | Hz |
Phase | 1 | ˜ |
Voltage | 230 | V |
Maximum unit power | 163 | W |
Sound pressure level at 3 m distance | 35 | dBА |
Air capacity | 230 | m³/h |
RPM | 2720 | min-1 |
Maximum transported air temperature | -25…+50 | °С |
Heat recovery efficiency | 72...94 | % |
Insulation | EPP 15…26 mm | - |
Casing material | expanded polypropylene | - |
Filter: extract | G4 | - |
Filter: supply | G4, F8 | - |
Connected air duct size | 125 | mm |
Weight | 13.5 | kg |
Heat exchanger type | counter-flow | - |
Heat exchanger material | enthalpy | - |
SEC Class | C | - |
Capacity diagram
Capacity diagram
- Selection method:
- Air flow:
- Pressure:
Operating point
- Air flow: --
- Pressure: ---
Files archieve
Downloads
Select document type
Dimensions
Characteristics
Parameter | Value | Measurement unit |
---|---|---|
∅D | 125 | mm |
B | 590 | mm |
H | 893 | mm |
L | 316 | mm |
Additional technical data
Additional technical data
Sound power level, A – weighted | Gen. | Octave-frequency band [Hz] | LpA, 3 m dBA | LpA, 3 m dBA | ||||||||
dBA | 63 | 125 | 250 | 500 | 1000 | 2000 | 4000 | 8000 | ||||
LWA to supply inlet | dBA | 82 | 65 | 63 | 65 | 80 | 74 | 74 | 68 | 64 | ||
LWA to supply outlet | dBA | 66 | 60 | 56 | 55 | 63 | 58 | 49 | 40 | 33 | ||
LWA to exhaust inlet | dBA | 82 | 64 | 67 | 71 | 81 | 77 | 79 | 75 | 67 | ||
LWA to exhaust outlet | dBA | 70 | 51 | 64 | 62 | 68 | 60 | 60 | 50 | 42 | ||
LWA to environment | dBA | 56 | 39 | 47 | 46 | 54 | 46 | 46 | 44 | 40 | 35 | 45 |
Calculation of air temperature downstream of the heat exchanger:
t = toutd + khr * (textr - toutd) / 100,
where
toutd - outdoor air temperature [°C]
textr - extract air temperature [°C]
khr - heat exchanger efficiency (according to the diagram) [%]
Designation key
Designation key
Series | Rated air flow [m3 /h] | Mounting features | Casing design | Control |
VUT: ventilation with heat recovery VUE: ventilation with energy recovery |
230 |
V: vertical |
5: expanded polypropylene |
А3: P3-1-300 speed controller |
Accessories
Accessories
Model | G4 panel supply filter | F8 panel supply filter | Hydraulic U-trap |
VUT 230 V5 А4 | SF 264x182x18 G4 | SF 264x182x18 F8 | SH-32 |
VUE 230 V5 А4 | - |
Video