Login

Privacy Policy (GDPR)
Authorization
Not registered yet? Take advantages of registration:
Products saving in a binding to the projects
Product consultation from our experts - Online
Registration
Signup
By using this form, you confirm that you have read the site terms of use Terms of use and completely accept the terms of use

VENTS VK 150 EC


Inline centrifugal fan in plastic casing with the air capacity up to 630 m³/h.

  • Description
  • Characteristics
  • Capacity diagram
  • Downloads
  • Dimensions
  • Additional characteristics
  • Designation key
Description
Description
APPLICATIONS
  • Supply and exhaust ventilation and air conditioning systems of various premises requiring cost-saving controllable ventilation. 
  • The best ventilation solution for exhaust ventilation of bathrooms, kitchens and other humid premises.
  • Compatible with Ø 100, 125, 150, 200, 250 and 315 mm round air ducts.
DESIGN
  • Durable, impact-resistant and corrosion-free ABS-plastic casing.
  • Airtight terminal box for connection to power mains. 
  • VK … EC P is fitted with a built-in smooth speed controller and power cord with IEC C14 electric plug.
MOTOR
  • High-efficient electronically commutated direct current motors with backward curved blades.
  • Such motors are the most state-of-the-art energy saving solution.
  • Power consumption of EC motors is 35% less as compared to standard motors.
  • The fans with EC motors have excellent aerodynamic performance and low-noise operation.
  • EC motors are featured with high performance and total speed controllable range.
  • High efficiency reaching 90% is the premium advantage of the electronically-commutated motors.
  • The motors are equipped with ball bearings designed for at least 40 000 operating hours.
SPEED CONTROL
  • The fan is operated with an external 0-10 V control signal.
  • The air capacity is controlled depending on air temperature, pressure level, smoke content, etc.
  • The speed of the EC motor changes proportionally to fluctuations of the control parameter and the fan delivers a required air volume to the ventilation system.
  • Maximum fan speed does not depend on the current frequency.
  • The fan is compatible both with 50 or 60 Hz power mains.
  • The fans may be integrated into a unified data processing control system.
  • The specially designed software provides precise control of all the fans integrated into the system.
MOUNTING
  • The fans are designed for duct mounting in any point of the ventilation system with the casing mounted at any angle.
  • In case of vertical mounting a protective outer hood must be installed on the top. 
  • Fixation to the floor wall or ceiling is performed with the supplied mounting brackets.
  • Electric connection and installation must be performed in compliance with the manual and the wiring diagram on the terminal box.
VENTS VK EC fan kitchen ventilation example
Characteristics
Characteristics
Parameter VK 150 EC
Measurement unit
Voltage 1~230 V
Frequency 50/60 Hz
Sound pressure level at 3 m distance 45 dBА
Power consumption 82 W
Maximum air capacity 630 m³/h
Current 0.63 A
EC motor yes -
RPM 3400 min-1
Max. transported air temperature -25 +60 °С
Protection rating IP X4 -
Design centrifugal -
Duct diameter 150 mm
Weight 2.5 kg
Casing material plastic -
SEC Class B -
Duct for round air ducts -
Mounting Inline -
* To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor). -
Capacity diagram
Capacity diagram
  • Selection method:
  • Air flow:
  • Pressure:
Operating point
  • Air flow: --
  • Pressure: ---
Files archieve
Downloads
Select document type
  • Advertising and printing products
  • Certificates
  • Technical documentation
Name
"VENTS VK EC" product description 05-2022 (pdf 1.85Mb)
Download high quality image "VENTS VK EC (ErP 2015, 2016, 2018)" (psd 4.28Mb)
Download image "VENTS VK EC (ErP 2015, 2016, 2018)" for your website (png 391.06Kb)
"VENTS VK EC" user’s manual 04-2022 (V02-1EN-02) (pdf 1.2Mb)
Dimensions
Characteristics
VENTS  VK 150 EC
Parameter Value Measurement unit
∅D 150 /160 mm
ØD1 300 mm
B 310 mm
L 286 mm
L1 30 mm
L2 30 mm
L3 30 mm
Additional characteristics
Additional characteristics
Point on the diagram 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Power [W] 82 82 82 82 54 57 53 49 32 33 31 27 17 17 17 16 9 9 8 8

 

Sound power level, A-filter applied Sound pressure level at 3 m distance, A-filter applied Sound pressure level at 1 m distance, A-filter applied
Sound power level, A-weighted Gen. Octave frequency band [Hz]
  Hz 63 125 250 500 1000 2000 4000 8000 LpA, 3 m [dBA] LpA, 1 m [dBA]
LwA to inlet dBA 93 55 90 89 77 76 73 70 56 72 82
LwA to outlet dBA 93 55 91 88 74 73 68 67 54 72 82
LwA to environment dBA 66 26 48 58 61 60 59 51 39 45 55
Designation key
Designation key
Series Duct diameter Motor Options

VENTS VK EC

100; 125; 150; 200; 250; 315

ЕС
- synchronous electronically commutated motor
U: speed controller with electronic thermostat and temperature sensor integrated into the air duct. Equipped with power cord and IEC C14 electric plug.
Un: speed controller with electronic thermostat and external temperature sensor fixed on 4 m cable. Equipped with power cord and IEC C14 electric plug. 
P:
 built-in smooth speed controller and power cable with IEC C14 electric plug.
R: power cord with IEC C14 electric plug.

 

ErP data  
Overall efficiency η, [%]
Measurement category MC
Efficiency category EC
Efficiency grade N
Variable speed drive VSD
Power [kW]
Current [A]
Air flow [m3/h]
Static pressure [Pa]
Speed [n/min-1]
Specific ratio SR
Share your opinion

Questionnaire
How often do you use equipment selection program?