Characteristics
Parameter |
VKPI 2E 400*200 50 Hz |
VKPI 2E 400*200 60 Hz |
Measurement unit |
---|---|---|---|
Phase | 1 | 1 | ˜ |
Voltage | 230 | 230 | V |
Frequency | 50 | 60 | Hz |
Sound pressure level at 3 m distance | 45 | 47 | dBА |
Air capacity | 930 | 1070 | m³/h |
Power consumption | 138 | 200 | W |
Current | 0.6 | 0.88 | A |
RPM | 2600 | 2850 | min-1 |
Protection rating | IP X4 | IP X4 | - |
Design | centrifugal | centrifugal | - |
Transported air temperature | -25 ... +45 | -25 ... +45 | °С |
Weight | 24.5 | 24.5 | kg |
Number of poles | 2 | 2 | - |
Sound- and heat-insulated casing | yes | yes | - |
Casing material | galvanized steel | galvanized steel | - |
Width | 400 | 400 | mm |
Height | 200 | 200 | mm |
Duct | for rectangular air ducts | for rectangular air ducts | - |
Mounting | Inline | Inline | - |
Capacity diagram
Capacity diagram
- Selection method:
- Air flow:
- Pressure:
Operating point
- Air flow: --
- Pressure: ---
Files archieve
Downloads
Select document type
Dimensions
Characteristics
Parameter | Value | Measurement unit |
---|---|---|
В | 400 | mm |
B1 | 420 | mm |
B2 | 440 | mm |
B3 | 500 | mm |
H | 200 | mm |
H1 | 220 | mm |
H2 | 240 | mm |
H3 | 360 | mm |
L | 500 | mm |
Additional diagrams
Additional diagrams
Sound power level, A-filter applied | Sound pressure level at 3 meters, A-filter applied | Sound pressure level at 1 meters, A-filter applied | ||||||||||
General | Octave frequency band [Hz] | |||||||||||
Hz | 63 | 125 | 250 | 500 | 1000 | 2000 | 4000 | 8000 | LpA, 3 m [dBA] | LpA, 1 m [dBA] | ||
LwA to inlet | dBA | 75 | 64 | 70 | 70 | 66 | 61 | 61 | 58 | 51 | 54 | 64 |
LwA to outlet | dBA | 79 | 66 | 70 | 73 | 72 | 69 | 69 | 68 | 61 | 58 | 68 |
LwA to environment | dBA | 66 | 42 | 54 | 61 | 60 | 61 | 51 | 47 | 37 | 45 | 55 |
Designation key
Designation key
Series | Motor modification | Flange diameter [W*H] | ||
Number of poles | Phase | |||
VENTS VKP | I:sound- and heat-insulated casing | 2 4 |
E: single phase D: three phase |
400*200; 500*250; 500*300; 600*300; 600*350; 1000*500 |