Login

Privacy Policy (GDPR)
Authorization
Not registered yet? Take advantages of registration:
Products saving in a binding to the projects
Product consultation from our experts - Online
Registration
Signup
By using this form, you confirm that you have read the site terms of use Terms of use and completely accept the terms of use

VENTS VS 450 EC


Inline centrifugal fan in heat- and sound-insulated casing equipped with EC motors. Maximum capacity - 6800 m3/h.

  • Description
  • Characteristics
  • Downloads
  • Dimensions
  • Additional diagrams
  • Legend
  • BIM
Description
Description
APPLICATIONS
  • Supply and exhaust ventilation systems for various premises with energy-efficient and low-noise requirements. 

  • The VS EC fan design enables both inline and 90° air outlet due to changeable positions of the removable panels.

  • The aluzinc casing with high corrosionresistant properties and heat-insulating material enables outdoor installation of the fan.
DESIGN
  • The fan casing is made of aluminium frame, fastened with aluminium bends and removable double-skinned aluzinc panels, heat- and sound-insulated with 20 mm non-combustible mineral wool.

  • The connecting pipes that also serve as vibration absorbing connectors are available with round and square sections.

  • The round connecting pipes are fitted with rubber sealing rings.

  • The connecting pipes are not included into the delivery set and are available upon separate order.

     

MOTOR
  • The impellers with backward curved blades powered with high efficient electronically commutated (EC) motors with external rotor.

  • As of today, such motor type is the most advanced solution for energy saving.

  • EC motors are featured with high performance and the optimal control over the whole range of fan speeds.

  • Premium efficiency reaching up to 90% is the absolute advantage of electronically commutated motors.

Built-in functions and control
  • The fan is controlled with the external control signal 0-10 V (air capacity as a function of temperature level, pressure, etc.).

  • Should the control value factor get changed the EC motor changes its speed and the fan boosts as much air flow to the ventilation system as required.

  • Maximum speed of the fan does not depend on the current frequency and it can operate at 50 or 60 Hz mains supply.

  • The fans can be integrated to the unified PC control system.

  • The respective software allows controlling all the fan units with high accuracy and setting particular operation mode for each fan.

MOUNTING
  • The fans are designed for connection to rectangular or round air ducts with a flexible connector of respective cross section.

  • The fan can be fixed with supports, suspension or mounting bracket and it is suitable for any mounting position, on condition that the pointer on the fan casing matches the air motion direction in the system.

  • While mounting the fan provide enough access for its servicing.
OFFERED OPTIONS FOR FANS
VPG VVG KN-VS VPR-VS
       
Options Dimensions [mm]
VPG VVG KN-VS VPR-VS A A1 B B1 C ØD E F G
VPG 500/315 VVG 500х500 KN-VS 315-355 VPR-VS 315-355 490 478 470 458 445 315 458 225 600
VPG 500/355 VVG 500х500 KN-VS 315-355 VPR-VS 315-355 490 478 470 458 445 355 458 225 600
VPG 670/400 VVG 670x670 KN-VS 400-500 VPR-VS 400-500 660 648 640 628 615 400 628 321 770
VPG 670/450 VVG 670x670 KN-VS 400-500 VPR-VS 400-500 660 648 640 628 615 450 628 321 770
VPG 670/500 VVG 670x670 KN-VS 400-500 VPR-VS 400-500 660 648 640 628 615 500 628 321 770
VPG 800/560 VVG 800x800 KN-VS 560-630 VPR-VS 560-630 790 778 770 758 745 560 758 421 900
VPG 800/630 VVG 800x800 KN-VS 560-630 VPR-VS 560-630 790 778 770 758 745 630 758 421 900
   
VS EC fan gym ventilation example VS EC fan office ventilation example
Characteristics
Characteristics
Parameter VS 450 EC
Measurement unit
Highpowered motor Highpowered motor no -
Phase 1 ˜
Voltage 200-277 V
Frequency 50/60 Hz
Sound pressure level at 3 m distance 50 dBА
Power consumption 750 W
Current 3.3 A
RPM 1440 min-1
EC motor yes -
Max. transported air temperature -25 +60 °С
Protection rating IP X4 -
Maximum air flow capacity at cross directed Maximum air flow capacity at cross directed 6800 m³/h
Maximal air flow capacity at straight directed Maximal air flow capacity at straight directed 6460 m³/h
Design centrifugal -
Weight 46.3 kg
Duct diameter 450 mm
Sound- and heat-insulated casing yes -
Casing material aluzinc, aluminium -
Duct for square air ducts, for round air ducts -
Type supply and exhaust -
Mounting Inline -
Files archieve
Downloads
Select document type
  • Advertising and printing products
  • Certificates
  • Technical documentation
Name
"VENTS VS, VS EC" user's manual 08-2023 (V19EN-06) (pdf 3.99Mb)
"VENTS VS EC" product description 03-2021 (pdf 1.74Mb)
Download high quality image "VENTS VS EC (ErP 2015, 2016, 2018)" (psd 4.49Mb)
Download image "VENTS VS EC (ErP 2015, 2016, 2018)" for your website (png 468.23Kb)
Dimensions
Characteristics
VENTS VS 450 EC
Parameter Value Measurement unit
A 670 mm
Additional diagrams
Additional diagrams
Point Power [W]
1 574
2 750
3 750
4 750
5 337
6 458
7 557
8 502
9 178
10 242
11 294
12 265
13 79
14 107
15 130
16 117

 

Sound-power level   Octave-frequency band [Hz]
  Hz   General   63   125   250   500   1000   2000   4000   8000
LwA to inlet   dBA 79 48 70 71 73 72 70 65 62
LwA to outlet dBA 83 70 76 72 76 78 75 69 64
LwA to environment dBA 71 33 68 63 61 61 58 53 44

 

ƞ, [%]   MC   EC   N   VSD   [kW]   [A]   [m3/h]   [Pa]   [RPM]   SR
64.2   А   Static   76   Yes   0.750   3.3   4195   405   1440   1

 

Legend
Legend
Series Impeller diameter Motor
VENTS VS 315; 355; 400; 450; 500; 560; 630 ЕС - synchronous electronically commutated motor

 

ErP data  
Overall efficiency η,[%]
Measurement category MC
Efficiency category EC
Efficiency grade N
Variable speed drive VSD
Power [kW]
Current [A]
Air flow [m3/h]
Static pressure [Pa]
Speed [n/min-1]
Specific ratio SR
BIM
BIM

Share your opinion

Questionnaire
Is our site helpful for your business development?