Login

Privacy Policy (GDPR)
Authorization
Not registered yet? Take advantages of registration:
Products saving in a binding to the projects
Product consultation from our experts - Online
Registration
Signup
By using this form, you confirm that you have read the site terms of use Terms of use and completely accept the terms of use

VENTS VUT 1500 WH-4


Air handling unit with the air flow up to 1700 m³/h and heat recovery efficiency up to 77 % in sound-proof and heat-insulated casing with water heater

  • Description
  • Characteristics
  • Capacity diagram
  • Downloads
  • Dimensions
  • Additional characteristics
  • Designation key
  • Accessories
Description
Description
DESCRIPTION
  • The VUT WH air handling units with a water heater are used in ventilation and air conditioning systems in commercial, office and other public or industrial premises that require an economical solution and a controlled ventilation system.
CASING
  • The casing is made of aluzinc steel with 25 mm thick mineral wool heat- and sound-insulating layer.
FILTER
  • Two G4 panel filters for extract air ventilation are supplied with the unit.
FANS
  • The units are equipped with supply and exhaust centrifugal double-inlet fans with forward curved blades and built-in thermostat with automatic restart.
HEAT EXCHANGER
  • The heat exchangers have high efficiency and are made of polysterene.
  • The unit is also equipped with the drain pan for condensate drainage.
HEATER
  • The water heater.
  • The water heaters are designed for max. operating pressure 1.0 MPa (10 bar) and max. heat medium operating temperature 95 °C.
AUTOMATION AND CONTROL SYSTEM
  • The unit incorporates an integrated automation and control system with a multi-functional control panel with LCD display.
  • The standard delivery set includes 10 m connection cable for connection to the remote control panel.
CONTROL AND PROTECTION FUNCTIONS
  • Control from the control panel: switching on/off, threespeed fan selection, selecting heating/cooling modes (if connected to duct heater); room temperature display.
  • Maintaining supply air temperature set from the control panel by controlling the circulation pump and actuating the heat medium regulating valve; input from the heat medium flow switch (pump alarm).
  • Safe start-up/ shutdown of the fans, warming up of the water heater before start-up; return heat medium temperature control when the fan is off.
  • Freezing protection of the water heating coils by the exhaust temperature sensor and the return heat medium temperature sensor.
  • Control of the compressor and condensing unit of the water cooler by the room temperature sensor (for the models equipped with a duct air cooler).
  • Actuating the external air dampers with a return spring.
  • Unit operation according to week schedule (set at the system setup).
  • Unit shut down at signal from the fire alarm system.
  • Smooth bypass damper control in the bypassing mode to prevent the heat exchanger freezing.
MOUNTING
  • The unit is designed for indoor mounting.
  • While mounting the unit provide the correct condensate collection and drainage.
  • Access for the unit servicing and filter cleaning is from the side panels on the left from supply air side.
Characteristics
Characteristics
Parameter VUT 1500 WH-4
Measurement unit
Frequency 50/60 Hz
Phase 1 ˜
Voltage 230 V
Maximum fan power 2 pcs. x 490 W
Air capacity 1700 m³/h
Number of water (glycol) coil rows 2 or 4 -
Fan current 2 pcs. x 2.15 A
Total unit power 980 W
Total unit current 4.3 A
RPM 1100 min-1
Maximum transported air temperature -25...+40 °С
Sound pressure level at 3 m distance 49 dBА
Casing material aluzinc -
Heating water heating -
Insulation 50 mm mineral wool -
Filter: extract G4 -
Filter: supply G4 -
Connected air duct size 315 mm
Weight 99 kg
Heat recovery efficiency up to 77 %
Heat exchanger type cross-flow -
Heat exchanger material polystyrene -
Type supply and exhaust with heat recovery -
Mounting floor mounting -
Capacity diagram
Capacity diagram
  • Selection method:
  • Air flow:
  • Pressure:
Operating point
  • Air flow: --
  • Pressure: ---
Files archieve
Downloads
Select document type
  • Advertising and printing products
  • Certificates
  • Technical documentation
Name
Download high quality image "VENTS VUT WH" (psd 2.95Mb)
"VENTS VUT EH, VENTS VUT WH" product description 01-2023 (pdf 3.88Mb)
"Control system for air supply and air handling units based on Freemax controllers and AC208A2 sensor control panels" user's manual 07-2023 (V99EN-03) (pdf 7.14Mb)
"VENTS VUT WH" user's manual 07-2023 (V45-1EN-08) (pdf 2.84Mb)
Download image "VENTS VUT WH" for your website (png 649.56Kb)
Dimensions
Characteristics
VENTS VUT 1500 WH-4
Parameter Value Measurement unit
∅D 314 mm
B 842 mm
B1 581 mm
B2 320 mm
B3 520 mm
H 814 mm
H1 947 mm
H2 201 mm
H3 595 mm
L 1345 mm
L1 1388 mm
L2 1445 mm
Additional characteristics
Additional characteristics
Sound-power level Octave-frequency band [Hz]
  Hz Gen 63 125 250 500 1000 2000 4000 8000
LwA to inlet dBA 64 72 67 65 62 65 56 55 48
LwA to outlet dBA 66 76 72 70 61 64 60 63 55
LwA to environment dBA 46 54 54 48 39 39 34 31 27
Designation key
Designation key
Series Rated air flow [m³/h] Heater type Duct connection Row number of the heater Service side (for VUT 1500 WH, VUT 2000 WH)
VENTS VUT 350; 500; 530; 600; 800; 1000; 1500; 2000 W: water H: horizontal 2: two rows
4: four rows
L: left side
R: right side
Accessories
Accessories
Model G4 panel filter Silencers Back valves Air dampers Clamps Summer blocks
VUT 800 WH-4 SF 550x253x48 G4 SR 250 600/900/1200 SRF 250 600/900/1200 KOM 250 KR 250 C 250 VL C4 300/300*2
VUT 1000 WH-4 SF 780x273x48 G4 SR 315 600/900/1200 SRF 315 600/900/1200 KOM 315 KR 315 C 315 VL C4 300/384
VUT 1500 WH-4 SF 550x253x48 G4 SR 250 600/900/1200 SRF 250 600/900/1200 KOM 250 KR 250 C 250 VL C4 300/300*2
VUT 2000 WH-4 SF 780x273x48 G4 SR 315 600/900/1200 SRF 315 600/900/1200 KOM 315 KR 315 C 315 VL C4 300/384
Share your opinion

Questionnaire
How often do you use equipment selection program?