VENTS VUT 180 P5B EC


Heat recovery air handling unit in sound- and heat-insulated casing. Air flow up to 220 m³/h. Heat recovery efficiency up to 98 %.

  • Description
  • Characteristics
  • Capacity diagram
  • Downloads
  • Dimensions
  • Additional characteristics
  • Designation key
  • Accessories
Description
Description
DESCRIPTION CASING
  • The air handling units are the fully featured ventilation units with heat recovery for air filtration, fresh air supply and stale air extract.
  • The casing is made of expanded polypropylene (EPP) possessing high heat- and sound-insulating properties.
FILTER FANS
  • Two built-in G4 and F7 filters provide efficient supply air filtration.
  • The G4 filter is used for extract air filtration.
  • Efficient electronically commutated motors with external rotor and impeller with forward curved blades.
  • Such motors are the most state-of-the-art energy saving solution.
HEAT EXCHANGER  
  • The VUT 180 P5B EC units are equipped with a counter-flow polystyrene heat exchanger.

  • The VUE 180 P5B EC units are equipped with an enthalpy counter-flow heat exchanger.

BYPASS AUTOMATION
  • The VUT/VUE 180 P5B EC A14/A21 units are equipped with a bypass for summer cooling.
FREEZE PROTECTION
  • For VUT/VUE 180 P5B EC A14 the freeze protection is realized by means of shutdown the supply fan.
  • For VUT/VUE 180 P5B EC A21 the freeze protection is realized by means of turning the preheater on (available as an accessory).
MOUNTING
  • The unit is designed for suspended ceiling, wall horizontal or vertical installation using the fixing brackets.
  • The mounting position of the unit must provide service access for maintenance and repair.
  • The VUT/VUE 180 P5B EC A21 units are equipped with integrated control system.
  • The A21 controller allows integrating the unit into the Smart Home system or BMS (Building Management Systems).
  • The unit is controlled via Wi-Fi by means of the VENTS Home mobile application that must be downloaded.
  • The VUT/VUE 180 P5B EC A14 units are equipped with integrated control system and the A14 wall-mounted control panel with LED indication.
CONTROL AND AUTOMATION  
Functions A21 A14
Wi-Fi control via mobile application + -
Control via external wired control panel Option (A22)
А14
Wired remote LCD control panel
Option (А25)
-
Control via external wireless control panel Option (A22 Wi-Fi)
-
BMS
RS-485
Wi-Fi
Ethernet
MODBUS (RTU, TCP)
-
Service Vents Cloud Server + -
Speed selection + +
Filter replacement indication According to filter timer According to filter timer
Alarm indication Full alarm description in the mobile application Alarm LED indication
Week scheduled operation + -
Bypass Auto -
Manual Manual
Timer + -
Boost mode + -
Fireplace mode + -
Freeze protection Cyclic shutdown of supply fan Cyclic shutdown of supply fan
Preheating (option) -
Reheater connection Option -
Cooler connection Option -
Control of minimum supply air temperature + -
Humidity control Option Option
CO2 control Option Option
VOC control Option -
PM2.5 control Option -
Fire detector Option Option

Option. The function is available in case of mounting a respective accessory.

UNIT DESIGN  
APPLICATION OPTIONS  
Characteristics
Characteristics
Parameter VUT 180 P5B EC
Measurement unit
Frequency 50/60 Hz
Phase 1 ˜
Voltage 230 V
Maximum unit power 87 W
Maximum unit current 0.71 A
Air capacity 220 m³/h
RPM 2200 min-1
Heat recovery efficiency 86...98 %
Transported air temperature -25 ... +40 °С
Sound pressure level at 3 m distance 33 dBА
Casing material expanded polypropylene -
Insulation EPP 30-15 mm -
Filter: extract G4 -
Filter: supply G4, F7 -
Connected air duct size 150 mm
Weight 14 kg
Heat exchanger type counter-flow -
Heat exchanger material polystyrene -
SEC Class A+ -
Capacity diagram
Capacity diagram
  • Selection method:
  • Air flow:
  • Pressure:
Operating point
  • Air flow: --
  • Pressure: ---
Files archieve
Downloads
Select document type
  • Advertising and printing products
  • Certificates
  • Technical documentation
Name
Software "Setting air handling units with automation A14 and A15" (rar 17.47Mb)
"VENTS VUT/VUE 180 P5B EC" product description 01-2023 (pdf 2.52Mb)
"VENTS VUT/VUE 180 P5(B) EC" user's manual 10-2023 (V170EN-08) (pdf 2.36Mb)
Download high quality image "VENTS VUT/VUE 180 P5B EC (ErP 2015, 2016, 2018)" (psd 3.74Mb)
Download image "VENTS VUT/VUE 180 P5B EC (ErP 2015, 2016, 2018)" for your website (png 322.65Kb)
"Sensor control panel A14/A15" user’s manual 04-2019 (V55-7EN-02) (pdf 1.16Mb)
"Wireless control system A21" user’s manual 09-2022 (V55-8EN-04) (pdf 415.1Kb)
Dimensions
Characteristics
VENTS VUT 180 P5B EC
Parameter Value Measurement unit
∅D 150 mm
∅D1 19 mm
B 600 mm
B2 326 mm
L 900 mm
L1 1009 mm
H 264 mm
H1 38 mm
H2 302 mm
Additional characteristics
Additional characteristics

 

Point Power [W] Sound pressure level at 3 m (1 m) distance [dBA]
1 77 33 (43)
2 64 33 (43)
3 53 32 (42)
4 31 29 (39)
5 30 28 (38)
6 26 27 (37)
7 14 23 (33)
8 13 21 (31)
9 12 19 (29)

 

Exhaust air spigot configuration Air flow [l/s] Specific fan power [W/l/s] Recovery efficiency [%]
Kitchen + 1 additional wet room 21 0.90 88
Kitchen + 2 additional wet rooms 29 1.00 86
Kitchen + 3 additional wet rooms 37 1.20 85

 

A-weighted sound power level Gen. Octave-frequency band [Hz] LpA, 3 m [dBA] LpA, 1 m [dBA]
dBA 63 125 250 500 1000 2000 4000 8000    
LwA to supply air inlet dBA 59 27 46 54 55 53 48 44 35    
LwA to supply air outlet dBA 60 27 46 54 55 52 49 44 35    
LwA to exhaust air inlet dBA 55 25 41 50 51 44 42 39 30    
LwA to exhaust air outlet dBA 55 26 41 51 51 44 42 39 31    
LwA surrounding dBA 54 18 36 47 49 48 43 37 33 33 43

Calculation of air temperature downstream of the heat exchanger:

t = toutd + khr * (textr - toutd) / 100,

where
toutd is outdoor air temperature [°C]
textr is extract air temperature [°С]
khr is heat exchanger efficiency (according to the diagram) [%]

Designation key
Designation key
Series Rated air flow [m³/h] Mounting type Casing design Bypass Motor type Control
VUT: ventilation with heat recovery
VUE: ventilation with energy recovery
180 P: supended mounting 5: expanded polypropylene B: integrated bypass ЕС: synchronous electronically commutated motor А14
А21
Accessories
Accessories
Model G4 panel filter F7 panel filter LCD control panel Control panel Wi-Fi controllable control panel Internal humidity sensor CO2sensor with indication CO2 sensor Humidity sensor VOC sensor (0-10 V) CO2 sensor (0-10 V) Humidity sensor (0-10 V) Reheater Preheater Syphon kit Air damper Electric actuator
VUT 180 P5B ЕС A21 SF 214x186x18 G4 SF 214x186x48 F7  А25  А22 А22 Wi-Fi HV2 CO2-1 CO2-2 HR-S DPWQ 30600 DPWQ 40200 DPWC 11200 NKD 150 NKP 150 SH-32 KRV 150 LF230
VUE 180 P5B ЕС A21
VUT 180 P5B ЕС A14 –  SH-32
VUE 180 P5B ЕС A14  
Share your opinion

Questionnaire
Is our site helpful for your business development?