Login

Privacy Policy (GDPR)
Authorization
Not registered yet? Take advantages of registration:
Products saving in a binding to the projects
Product consultation from our experts - Online
Registration
Signup
By using this form, you confirm that you have read the site terms of use Terms of use and completely accept the terms of use

Ceiling bathroom fans VENTS CBF LP DC series

Ceiling bathroom fans VENTS CBF LP DC series
Ceiling bathroom fans with maximum air flow up to 187 m³/h.
Model features
  • Silent mode
  • DC-Motor
  • Humidity sensor
  • Motion sensor
  • Centrifugal fan
  • Smooth-speed-control
  • Description
  • Modifications
  • Capacity diagram
  • Downloads
  • Accessories
Description
Description
APPLICATION

  • DC motor with low energy demand.
  • Constant air flow.
  • Low noise level.
  • Wide speed setting range.
  • The modular design enables easy connection of a humidity or motion sensor.
  • Continuous or periodic exhaust ventilation of bathrooms, showers, and other utility spaces.
  • Designed for high-resistant ductworks.
  • Ingress protection rating: IPX4.
  • Compatible with Ø 100 mm air ducts.
MOTOR  
  • The CBF LP DC fan features a high-efficient low-watt direct current motor with overheating protection. The constant air flow technology provides required air flow in a wide range of static pressure.
  • Maintenance-free bearings contain enough grease for 40 000 hrs of continuous operation.
DESIGN  
  • The casing is made of galvanized steel.
  • The modular design enables easy retrofitting with optional humidity and motion sensors (except for the basic model) or a grille with a light.
  • The centrifugal impeller is equipped with forward curved blades for high operating pressure and low noise.
  • The impeller of the motor is made of high-quality durable ABS plastic.
  • The fan features a gravity backdraft damper to prevent backdraft.
  • Easily removable plastic grille ensures easy installation and maintenance of the fan.
  • The modular grille design enables easy connection of an optional humidity or motion sensor.

OPTIONS
Humidity sensor Motion sensor
  • The CBF LP DC is equipped with an adjustable turn-on and turn-off delay timer. A humidity sensor or a motion sensor (available separately) can be optionally connected to this fan modification.
CONTROL  

The built-in control panel of the CBF LP DC fans enables setup of the following parameters:

  • timer-based turn-on delay
  • timer-based turn-off delay
  • humidity level
  • air flow in Modes 1 and 2
Name Adjustment range for operation modes 1 and 2
CBF LP 110 DC OFF / Speed 1 / Speed 6

Control panel for CBF LP DC fans

Manual control

  • The fan is controlled by means of the P2-10 speed switch (available separately).

Automatic control

  • Timer: the fan constantly operates in Mode 1. When the light switch is closed, the fan switches to Mode 2 after the end of the turn-on delay time (from 0 to 3 minutes). Upon the light switch opening, the built-in turn-off delay timer keeps the fan running in Mode 2 from 1 to 90 minutes. On elapsing of this period the fan reverts to Mode 1.
  • Timer and humidity sensor (available separately): the fan constantly operates in Mode 1. If the indoor humidity level exceeds the sensor threshold value set in the 50-90 % range, the fan switches to Mode 2. When the humidity level reverts to the pre-set value, the built-in turn-off delay timer keeps the fan running in Mode 2 from 1 to 90 minutes. On elapsing of this period the fan reverts to Mode 1.
  • Timer and motion sensor (available separately): the fan constantly operates in Mode 1. If the motion sensor detects movement within its range, the fan goes to Mode 2. When the movement is no longer detected, the built-in turnoff delay timer keeps the fan running in Mode 2 from 1 to 90 minutes. On elapsing of this period the fan reverts to Mode 1.
MOUNTING  
  • The fan is designed for ceiling mounting.
  • The fan is attached to the ceiling joists with spacer brackets and self-tapping screws.
  • The flexible air duct is connected to the fan exhaust spigot through a clamp.
  • The reduced casing height allows fans to be installed in ceilings with a thickness of minimum 140 mm.
 
Modifications
Modification name
Humidity sensor
Timer
Motion sensor
DC Motor
+
Capacity diagram
Capacity diagram
  • Selection method:
  • Air flow:
  • Pressure:
Operating point
  • Air flow: --
  • Pressure: ---
Downloads
Downloads
Select document type
  • Advertising and printing products
  • Certificates
  • Technical documentation
Name
"VENTS CBF LP DC, VENTS CBF LP DC Light" product description 06-2019 (pdf 3.25Mb)
Download high quality image "VENTS CBF LP DC" (psd 2Mb)
Download image "VENTS CBF LP DC" for your website (png 520.78Kb)
"VENTS CBF LP DC, VENTS CBF LP DC Light" user's manual 05-2021 (V183EN-01) (pdf 2.55Mb)
Accessories
Accessories
Name Accessory image Description CBF 110 DC
P2-10 Speed switch
TH CBF Humidity sensor
TR CBF Motion sensor
MVM 102 bVs N Stainless steel ventilation hood Ø 100 mm
MV 102 V ASA ASA-plastic ventilation hood Ø 100 mm
Polyvent 660 102/3 Flexible air duct Ø 100 mm, 3 m long
CB 100 Quick-detachable stainless steel clamp Ø 90-110  mm
Share your opinion

Questionnaire
How often do you use equipment selection program?