FEATURES |
|
- Efficient solution for supply and exhaust ventilation of enclosed spaces.
- Electric pre-heater or post-heater variant available for cold climate conditions.
- Heat exchanger with an enthalpy membrane variant available for humid and hot climate conditions.
- Low-energy ЕС fans.
- Excellent noise control (25-38 dBA).
|
- Supply air purification ensured by two built-in G4 and F8 filters (optional H13).
- Upgradeable with an exhaust duct to provide air extraction from the bathroom.
- Easy installation.
- Compact size.
- Modern design.
|
DESIGN |
|
|
CASING |
|
- Polymer coated metal casing decorated with an acrylic front panel.
- Thanks to the modern design the unit can seamlessly blend with most any interior design.
- Heat and sound insulation is ensured by a layer of 10 mm cellular synthetic rubber.
- The front panel provides convenient access for filter maintenance and has a lock for extra security.
|
- The unit has two ø 100 mm inlet and outlet pipes for fresh air intake and stale air extraction outside.
- The third ø 100 mm pipe (included) can be additionally fitted to the unit to connect the exhaust air duct from the bathroom.
|
AIR FILTRATION |
AIR DAMPERS |
- Supply air cleaning is provided by G4 and F8 panel filters (PM2.5 > 75 %).
- To meet more stringent air purity requirements an F8 filter can be replaced with an H13 (PM2.5 > 95 %) (purchased separately).
- Extract air is cleaned by a panel-type G4 filter.
|
- The unit is equipped with supply and exhaust air dampers which activate automatically to prevent drafts while the unit is off.
|
FANS |
|
- The units feature efficient electronically commutated (ЕС) motors with external rotor and impellers with forward curved blades.
- These state-of-the-art motors offer the very best in energy efficiency today.
|
- EC motors are characterised with high performance and optimum control across the entire speed range.
- In addition to that the efficiency of electronically commutated motors reaches very impressive levels of up to 90 %.
|
NE MICRA 100 HEATER FOR CONDENSATE FREEZING PROTECTION (OPTIONAL) |
- Operation in a cold climate may result in condensate freezing in the exhaust air duct and the external hood.
|
- Therefore, it is recommended to install the NE Micra 100 heater (purchased separately) to prevent icing.
|
PRE-HEATING |
POST-HEATING |
- Micra 100 units are equipped with an electric pre-heater which protects the heat exchanger from freezing.
|
- Micra 100 E1 units feature an electric post-heater to raise the supply air temperature as necessary.
|
HEAT EXCHANGER |
|
- Micra 100 units are equipped with a counter-flow heat exchanger with a polystyrene core.
- In the cold season the extract air heat is captured and transferred to the supply air stream which reduces the ventilation-generated heat losses.
- However, this process may be associated with condensation which is collected in a special drain pan and evacuated outside via the exhaust air duct.
- In the warm season the ambient air heat is transferred to the exhaust air stream.
- This allows for a considerable reduction of the supply air temperature which, in turn, reduces the air conditioning load.
|
- Micra 100 ERV units are equipped with a counter-flow heat exchanger with an enthalpy membrane.
- In the cold season the extract air heat and moisture are transferred to the supply air stream through the enthalpy membrane reducing the heat losses from ventilation.
- Consequently, it is the ambient air heat and moisture transferred to the exhaust air stream through the enthalpy membrane in the warm season.
- This allows for a considerable reduction of the supply air temperature and humidity which, in turn, reduces the air conditioning load.
|
CONTROL AND AUTOMATION |
OPERATING LOGIC |
- Freeze protection
- There are two types of freeze protection available to protect the heat exchangers in the cold season.
- Micra 100 features an exhaust air temperature sensor downstream of the heat exchanger which disables the supply fan to let the warm exhaust air raise the heat exchanger temperature.
- Once the heat exchanger temperature has returned to normal, the supply fan is re-enabled and the unit reverts to normal operation.
- Micra 100 E units are equipped with an electric pre-heater which warms up the supply air upstream of the heat exchanger to prevent its freezing.
- These features ensure a continuous balanced air exchange regardless of ambient air temperature variations.
- Control
- The units are equipped with a control panel.
- Remote control panels are supplied as standard.
|
- Following functions are available:
|
Micra 100 Micra 100 E |
Micra 100 E1 |
Speed selection |
+ |
+ |
Filter replacement indication |
+ |
+ |
Alarm indication |
+ |
+ |
Speed setup |
+ |
+ |
Timer |
+ |
+ |
Weekly schedule |
+ |
+ |
Post-heating enabled/disabled |
- |
+ |
Supply air temperature setup |
- |
+ |
|
APPLICATION OPTIONS |
|
- Each space requiring proper ventilation is equipped with a single or several Micra 100 units.
- A single unit is capable of ensuring efficient ventilation in spaces with floor area up to 100 m2.
|
- Micra 100 units can be upgraded with a bathroom exhaust air duct.
- To enable such a configuration the units can be additionally equipped with the optional ø 100 mm fitting pipe (supplied as standard).
|
Micra 100 deployment in a compact residential space
|
Micra 100 application in an office space
|