Description
Description
APPLICATIONS      
  • Continuous or periodic exhaust ventilation of bathroom, showers, kitchens and other utility spaces.
  • Ventilation shaft mounting or duct connection.
  • Low to medium air flow motion for short distances at low air resistance.
  • Compatible with 100, 125 and 150 mm air ducts.
   
  Fan off - louver shutters CLOSED Fan on - louver shutters OPEN  
DESIGN      
  • Modern design and aesthetic look.
  • The casing, impeller and front panel are made of high-quality and durable UV-resistant ABS plastic.
  • Various decorative natural aluminium plates.
  • The thermal actuator provides smooth opening and closing of the automatic louvre shutters that prevent air back drafting.
  • The impeller design enhances the fan efficiency and prolongs the motor service life.
  • Protection rating IP 24.
MOTOR      
  • Reliable motor with low energy demand
  • Designed for continuous operation and requires no maintenance.
  • Equipped with overheating protection.
CONTROL      

Manual: 

  • The fan is controlled with a room light switch (not included into delivery set).
  • The fan is controlled with a built-in pull cord switch "V". This option is not applicable for ceiling mounting.
  • Speed control is possible through a thyristor speed controller (see Electrical Accessories). Several fans may connected to the same controller. Speed controllers can not be connected to the fans with TTHTPVTVTH modification.

Automatic:

  • Speed control with a an electronic control unit BU-1-60, refer Electric accessories. The control unit is available upon separate order.
  • Fan control with a turn-off delay timer "T" that enables fan running from 2 to 30 minutes after turning the fan off.
  • Fan control with a humidity sensor and turn-off delay timer "TH" that enables fan switching on and running until the indoor humidity drops below the set point adjustable from 60% to 90% and subsequent fan running within the set time before turning off.
MOUNTING FEATURES  
  • The fan is mounted directly into the ventilation shaft.
  • Flexible duct connection is recommended in case of the remote ventilation shaft location.
  • The air duct is connected to the fan exhaust flange through a clamp.
  • Fixing with screws.
  • Suitable for ceiling mounting.
  • The step-down transformer (TRF 220/12-25) enables connection of a low-voltage fan 12 V / 50 Hz to 220 V / 50 Hz power mains. Available upon separate order.
MOUNTING EXAMPLE  
Modifications
Ball bearing motor
Timer
Humidity sensor
Pull-cord switch
High-powered fan
5-blade low-noise impeller
Safe voltage (12 V)
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
Capacity diagram
Capacity diagram
  • Selection method:
  • Air flow:
  • Pressure:
Operating point
  • Air flow: --
  • Pressure: ---
Downloads
Downloads
Select document type
  • Advertising and printing products
  • Certificates
  • Technical documentation
Name
Download high quality image "VENTS LD Auto" (psd 2.19Mb)
Download image "VENTS LD Auto" for your website (png 419.5Kb)
"VENTS LD Auto" product description 09-2015 (pdf 4.25Mb)
Download high quality image "VENTS LDA Auto" (psd 2.46Mb)
Download high quality image "VENTS LDA Auto Chrome" (psd 1.94Mb)
Download high quality image "VENTS LDA Auto Gold" (psd 2.24Mb)
Download image "VENTS LDA Auto" for your website (png 694.34Kb)
Download image "VENTS LDA Auto Chrome" for your website (png 337.92Kb)
Download image "VENTS LDA Auto Gold" for your website (png 436.12Kb)
“VENTS M,M1,M3,MA,LD Auto,Modern Auto” user's manual 2013 (V01-(M model)EN-01) (pdf 1.85Mb)
Certificates
Certificates
<p>
	Mark of conformity to the European Quality Standards and Electrical Safety issued by Association for Technical Inspection (Technischer Überwachungsverein, Germany).</p>

Mark of conformity to the European Quality Standards and Electrical Safety issued by Association for Technical Inspection (Technischer Überwachungsverein, Germany).

<p>
	CE mark means that the equipment is produced in compliance with the quality and safety standards provided by EU regulations for the given product type (marked by manufacturer).</p>

CE mark means that the equipment is produced in compliance with the quality and safety standards provided by EU regulations for the given product type (marked by manufacturer).

<p>
	Mark of conformity to the Polish Quality Standards and electrical safety issued by PCBC (Polish center for testing and certification). </p>

Mark of conformity to the Polish Quality Standards and electrical safety issued by PCBC (Polish center for testing and certification).

<p>
	Mark of conformity to the Slovak Quality Standards and electrical safety issued by EVPU (Slovakia).</p>

Mark of conformity to the Slovak Quality Standards and electrical safety issued by EVPU (Slovakia).

<p>
	Mark of conformity to the Ukrainian Quality Standards and electrical safety issued by UkrTEST.</p>

Mark of conformity to the Ukrainian Quality Standards and electrical safety issued by UkrTEST.

<p>
	Mark of conformity of the goods subject to obligatory certification in DSTR system as well as technical norms and standards acting in Russian Federation. Confirmed by the RosTEST certificates (Moscow). </p>

Mark of conformity of the goods subject to obligatory certification in DSTR system as well as technical norms and standards acting in Russian Federation. Confirmed by the RosTEST certificates (Moscow).

<p>
	Insulation class: double insulation.</p>

Insulation class: double insulation.

<p>
	Equipment protection rating.</p>

Equipment protection rating.

<p>
	Applicance protection class.</p>

Applicance protection class.

<p>
	Equipment protection rating.</p>

Equipment protection rating.

<p>
	Equipment protection rating.</p>

Equipment protection rating.

RoHS (Restriction of Hazardous Substances Directive) is the directive on the restriction of the use of certain hazardous substances, was adopted in February 2003 by the European Union. RoHS (Restriction of Hazardous Substances Directive) is the directive on the restriction of the use of certain hazardous substances, was adopted in February 2003 by the European Union.
<p>
	Equipment protection rating.</p>

Equipment protection rating.

<p>
	Equipment protection rating.</p>

Equipment protection rating.

<p>
	Equipment protection rating.</p>

Equipment protection rating.

Legend
Legend
Picture symbol   Designation   Modification description
  LD Auto L   The motor is equipped with ball bearings for long service life (appr. 40 thousand hours) and fan mounting at any angle. The bearings are maintenance-free and contain enough grease for the entire operating period.
  LD Auto turbo   High-powered motor.
  LD Auto press   5-blade low-noise impeller with improved aerodynamics for higher fan capacity.
  LD Auto 12   Equipped with a reliable low-voltage motor, 12 V.
  LD Auto T   Equipped with a turn-off delay timer adjustable from 2 to 30 minutes.
  LD Auto TH   Equipped with a turn-off delay timer adjustable from 2 to 30 minutes and a humidity sensor adjustable from 60% to 90%.
  LD Auto V   Equipped with a pull cord switch.
  LD Auto VT   Equipped with a pull cord switch and a turn-off delay timer adjustable from 2 to 30 minutes.
  LD Auto VTH   Equipped with a pull cord switch, turn-off delay timer adjustable from 2 to 30 minutes and a humidity sensor adjustable from 60% to 90%.
Share your opinion

Questionnaire
How often do you use equipment selection program?