Login

Privacy Policy (GDPR)
Authorization
Not registered yet? Take advantages of registration:
Products saving in a binding to the projects
Product consultation from our experts - Online
Registration
Signup
By using this form, you confirm that you have read the site terms of use Terms of use and completely accept the terms of use

VENTS VUT PB EC air handling units with heat recovery

VENTS VUT PB EC air handling units with heat recovery
Air handling units in heat- and sound-insulated casing. Air flow up to 410 m³/h. Heat recovery efficiency up to 94 %
Model features
  • Humidity sensor
  • ЕС-Motor
  • Air handling units with heat recovery
  • Description
  • Modifications
  • Downloads
  • Designation key
  • Accessories
Description
Description
DESCRIPTION
  • The VUT PB EC air handling units are the fully-featured ventilation units that ensure air filtration, fresh air supply and stale air extract.
CASING
  • Made of galvanised steel, internally filled with a 40 mm heat- and sound-insulating layer of mineral wool.
FILTER
  • Built-in panel filters with filtration class F7 provide efficient supply air filtration.
  • Panel filters with filtration class G4 provide extract air filtration.

FANS
  • High-efficient electronically-commutated motors with an external rotor and backward curved blades.
HEAT EXCHANGER
  • The units are equipped with a high-efficient counter-flow polystyrene heat exchanger.
  • In the cold season the extract air heat is captured and transferred to the supply air stream which reduces the ventilation-generated heat losses.

FREEZE PROTECTION
  • To protect the heat exchanger from freezing in the cold season, the unit has a Frost Protection mode based on the temperature sensor readings.
  • The Frost Protection mode is activated at an exhaust air temperature of +3 ˚C.
  • After temperature increase the unit returns to the previous operation mode.
  • In case of freezing danger, the supply fan is turned off in VUT 160/250/350 PB EC A14 units.
  • Three modes of freeze protection are available in VUT 160/250/350 PB EC A21 models:
    • gradual reduction of the supply fan speed
    • with the bypass
    • with the electric preheater (available as an accessory).
BYPASS
  • The units are equipped with a 100 % bypass which can be opened for summer cooling.
MOUNTING
  • The units are designed for ceiling or wall mounting (horizontal spigot orientation) in a position allowing condensate collection and removal into a special drain pan.
  • The access for filter maintenance and replacement is available from the bottom panel.
AUTOMATION
  • The VUT PB EC A21 units are equipped with an integrated automation system.
  • The A21 controller enables integration of the unit into the Smart Home System or BMS (Building Management Systems).
  • To control the unit via Wi-Fi, download the VENTS Home mobile app.
  • The VUT PB EC A14 units are equipped with an integrated automation system and a wall-mounted control panel A14 with LED indication.
CONTROL AND AUTOMATION
Functions A21 A14
Wired remote control panel Option (А22)
A14
Control via a wired remote LCD control panel Option (А25)
-
Wireless remote control panel Option (А22 Wi-Fi)
-
BMS RS-485
Wi-Fi
Ethernet
MODBUS (RTU, TCP)
-
Vents Cloud Server service + -
Control via Wi-Fi using a mobile application + -
Freeze protection + +
Bypass Auto + manual Manual
Week-scheduled operation + -
Filter replacement indication According to filter timer According to filter timer
According to filter clogging differential pressure switch readings
Alarm indication + +
Speed selection + +
Timers + -
RH% sensor Option Option
CO2 sensor Option Option
VOC sensor Option Option
PM2.5 sensor Option Option
Boost mode + -
Fireplace mode + -
Preheater connection Option -
Reheater connection Option -
Cooler connection Option -
Fire alarm sensor Option Option
Minimum supply air temperature control + -
APPLICATION OPTIONS  
Modifications
+
+
+
Downloads
Downloads
Select document type
  • Advertising and printing products
  • Certificates
  • Technical documentation
Name
"VENTS VUT PB EC" product description 01-2023 (pdf 1.67Mb)
Download high quality image "VENTS VUT PB EC (ErP 2015, 2016, 2018)" (psd 3.79Mb)
Download image "VENTS VUT PB EC (ErP 2015, 2016, 2018)" for your website (png 265.14Kb)
Software "Setting air handling units with automation A14 and A15" (rar 17.47Mb)
"VENTS VUT PB EC" user's manual 02-2023 (V108EN-04) (pdf 4.24Mb)
"Sensor control panel A14/A15" user’s manual 04-2019 (V55-7EN-02) (pdf 1.16Mb)
"Wireless control system A21" user’s manual 09-2022 (V55-8EN-04) (pdf 415.1Kb)
Designation key
Designation key
Series Rated air flow [m³/h] Installation type Bypass Motor type Service side Automation
VENTS VUT 160; 250; 350 P: suspended installation B: bypass EC: synchronous electronically commutated motor L: left
R: right
A14
A21
Accessories
Accessories
Model G4 panel filter F7 panel filter Control panel Control panel with Wi-Fi LCD control panel Indoor humidity sensor Outdoor CO2 sensor with indication Outdoor CO2 sensor
VUT 160 PB EC A14 SF 403x253x48 G4 SF 403x253x48 F7 - - - HV2 CO2-1 CO2-2
VUT 160 PB EC A21 A22 A22 WiFi  A25
VUT 250 PB EC A14 - -  - 
VUT 250 PB EC A21 A22 A22 WiFi A25
VUT 350 PB EC A14 SF 603x253x48 G4 SF 603x253x48 F7 - - -
VUT 350 PB EC A21 A22 A22 WiFi A25

 

Model Outdoor humidity sensor VOC sensor
(0-10 V)
COsensor
(0-10 V)
Humidity sensor
(0-10 V)
Electric heater for preheating Electric reheater Hydraulic U-trap Air damper Electric actuator
VUT 160 PB EC A14 HR-S - - - - - SH-32 KRV 125 LF230
VUT 160 PB EC A21 DPWQ30600 DPWQ40200 DPWС11200 NKP-125 NKD-125
VUT 250 PB EC A14 - - - - -
VUT 250 PB EC A21 DPWQ30600 DPWQ40200 DPWС11200 NKP-125 NKD-125
VUT 350 PB EC A14 - - - - - KRV 160
VUT 350 PB EC A21 DPWQ30600 DPWQ40200 DPWС11200 NKP-160 NKD-160
Share your opinion

Questionnaire
How often do you use equipment selection program?