Mode VoltagePower consumptionCurrentMaximum air capacity RPMSound pressure level at 3 m distanceMaximum transported air temperatureProtection ratingWeightFan currentSpigot sizeFrequency PowerVoltageCurrentRPMAir capacityPressureWeightIP CodeSound pressure level at 3 mVoltageMaximum air capacity RPMWeightPhasePressureFrequencyFrequencyMaximum transported air temperaturePower consumptionEngine TypeSpigot sizeCurrentSEC ClassPowerSEC ClassMotor protection ratingEngine TypeDuct diameterEC motorCasing materialOutdoor mountingSound-insulated casingDuctDesignTypeMountingSmoke removalSFPMaximum air capacityCurrentMax. transported air temperatureLow-powered motorElectric connection Number of intake spigotsAir capacity*
Min speed 1~230 - - 488 2550 34 - IP X4 - - - 50 - - - - - - - - - - - - - - - - - - - - - 0.15 - 34 - IP 20 - 150 , 160 - polymer - - for round air ducts mixed-flow - Inline - - 136 - -25...+55 - - - - -
Mid speed 1~230 - - 544 2704 35 - IP X4 - - - 50 - - - - - - - - - - - - - - - - - - - - - 0.16 - 37 - IP 20 - 150 , 160 - polymer - - for round air ducts mixed-flow - Inline - - 151 - -25...+55 - - - - -
Max speed 1~230 - - 600 2816 37 - IP X4 - - - 50 - - - - - - - - - - - - - - - - - - - - - 0.20 - 45 - IP 20 - 150 , 160 - polymer - - for round air ducts mixed-flow - Inline - - 167 - -25...+55 - - - - -
50 Hz 1~ 220-240 85 - 553 2600 50 - IP X4 6.60 - - 50 - - - - - - - - - - - - - - - - - - - - - - B - - - - 160 - polymer coated steel - - for round air ducts centrifugal , wall mounting , Inline - - - 0.38 -25 +40 - - 1 - -
60 Hz 1~ 220-240 107 - 610 2810 52 - IP X4 6.60 - - 60 - - - - - - - - - - - - - - - - - - - - - - B - - - - 160 - polymer coated steel - - for round air ducts centrifugal , wall mounting , Inline - - - 0.47 -25 +40 - - 1 - -
- - - - - - - - - - - - - - 220-240 0.16 2400 365 - 0.58 IP X4 42 - - - - - - 50; 60 - - 36 - 150 - - - - - 220-240V / 50Hz or 220-240V / 60Hz 150 - - - - - axial supply and exhaust Inline - - - - - - - - - -
- - - - - - - - - - - - - - 220-240 0.105 2400 188 - 0.81 IP 34 39 - - - - - - 50/60 - - 22 - 125 - - - - - 220-240V / 50-60Hz 125 - - - - - axial exhaust wall mounting , ceiling mounting - - - - - - - - - -
127 V - - - - - - - - - - - - - 127 0.338 2350 - - - IP 34 37 - - - 0.96 - - 60 - - 25 - 150 - - - - - 127-220 V/60 Hz 150 - - - - - axial exhaust wall mounting , ceiling mounting - - - - - - - - 240 -
220 V - - - - - - - - - - - - - 220 0.175 2350 - - - IP 34 37 - - - 0.96 - - 60 - - 25 - 150 - - - - - 127-220 V/60 Hz 150 - - - - - axial exhaust wall mounting , ceiling mounting - - - - - - - - 240 -
- - - - - - - - - - - - - - 220 0.105 2400 225 - 0.80 IP 24 37 - - - - - - 60 - - 24 - 120 - - - - - 220V / 60Hz 120 - - - - - axial exhaust wall mounting , ceiling mounting - - - - - - - - - -
- 230 155 - 904 - 63 25 +50 IP X4 6.1 - 200 60 - - - - - - - - - - - - - - 655 - - - - 220V / 60Hz - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - 220-240 0.117 2400 - - - IP 24 35 - - - 0.74 - - 50/60 - - 17.5 - 125 - - - - - 220-240V / 50-60Hz 125 - - - - - axial exhaust wall mounting , ceiling mounting - - - - - - - - 174 -
min 1~230 23 0.18 220 1950 28 - IP X4 1.35 - - 50/60 - - - - - - - - - - - - - - - - - - - - - - B - - - - 100 - plastic - yes for round air ducts mixed-flow - Inline - - - - 60 - - - - To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor).
max 1~230 37 0.27 280 2455 37 - IP X4 1.35 - - 50/60 - - - - - - - - - - - - - - - - - - - - - - B - - - - 315 - plastic - yes for round air ducts mixed-flow - Inline - - - - 60 - - - - To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor).
- 230 - - 622 - 65 55 IP X4 4.5 - 200 60 - - - - - - - - - - - - - - 437.5 - - - - 220V / 60Hz - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - 220-240 0.13 2400 265 - 0.96 IP 34 37 - - - - - - 50; 60 - - 24 - 150 - - - - - 220-240V / 50Hz or 220-240V / 60Hz 150 - - - - - axial exhaust wall mounting , ceiling mounting - - - - - - - - - -
- - - - - - - - - - - - - - 120 0.17 - 83 - - IP 24 36 - - - - - - 60 - - 13.68 120В / 60Гц 100 - - - - - - 100 - - - - - axial exhaust wall mounting , ceiling mounting - - - - - - - - - -
50 Hz 1~ 220-240 60 - 230 2605 35 - IP X4 2.7 - - 50 - - - - - - - - - - - - - - - - - - - - - - C - - IP44 - 125 - galvanized steel yes - for round air ducts centrifugal - outdoor mounting , wall mounting , Inline - - - 0.37 -25...+55 yes - - - To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor).
60 Hz 1~ 220-240 61 - 240 2720 36 - IP X4 2.7 - - 60 - - - - - - - - - - - - - - - - - - - - - - C - - - - 125 - galvanized steel yes - for round air ducts centrifugal - outdoor mounting , wall mounting , Inline - - - 0.37 -25 +50 yes - - - To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor).
- - - - - - - - - - - - - - 220 0.109 - 170 50 - - 41 - - - - - - 60 - - 16.56 220V / 60Hz 125 - - - - - - 125 - - - - - axial supply and exhaust Inline - - - - - - - - - -
- - - - - - - - - - - - - - 220-240 0.13 2400 298 - 0.8 IP X4 40 - - - - - - 50; 60 - - 24 - 150 - - - - - 220-240V / 50Hz or 220-240V / 60Hz 150 - - - - - axial supply and exhaust Inline - - - - - - - - - -
speed 1 - - - - - - - - - - - - - 220-240 0.14 1350 63 - - IP 55 30 - - - - - - 50 - 50 17 220В / 50Гц 80 - - - - - - 80 - - - - - centrifugal exhaust wall mounting , ceiling mounting - - - - - - 3×1.5 - - -
speed 2 - - - - - - - - - - - - - 220-240 0.18 1830 102 - - IP 55 35.2 - - - - - - 50 - 50 27 220В / 50Гц 80 - - - - - - 80 - - - - - centrifugal exhaust wall mounting , ceiling mounting - - - - - - 3×1.5 - - -
- - - - - - - - - - - - - - 120 0.4 - 258 50 - IP 24 43 - - - - - - 60 - - 33.4 120В / 60Гц 150 - - - - - - 150 - - - - - axial exhaust wall mounting , ceiling mounting - - - - - - - - - -
- - - - - - - - - - - - - - 230 0.035 - 78 - 0.52 IP 34 26 - - - - - - 50/60 - - 7 - 100 - - - - - 220-240V / 50-60Hz 100 - - - - - axial exhaust wall mounting , ceiling mounting - - - - - - - - - -
- - - - - - - - - - - - - - 220-240 0.1 2400 167 - 1.11 IP 34 34 - - - - - - 50/60 - - 16 - 125 - - - - - 220-240V / 50-60Hz 125 - - - - - axial exhaust wall mounting , ceiling mounting - - - - - - - - - -
- - - - - - - - - - - - - - 230 0.049 - 99 - 0.58 IP 45 24 - - - - - - 50; 60 - - 7.5 - 100 - - - - - 220-240V / 50Hz or 220-240V / 60Hz 100 - - - - - axial exhaust wall mounting , ceiling mounting - - - - - - - - - -
max - - - - - - - - - - - - - 220-240 0.063 2400 - - - IP 44 25 - - - 0.55 - - 50 - - 8.5 - 100 - - - - - 220-240V / 50Hz 100 - - - - - axial exhaust wall mounting - 0.34 25 - - - - - 90 -
min - - - - - - - - - - - - - 220-240 0.039 1850 - - - IP 44 22 - - - 0.55 - - 50 - - 6 - 100 - - - - - 220-240V / 50Hz 100 - - - - - axial exhaust wall mounting - 0.36 17 - - - - - 60 -
- - - - - - 55 - IP X4 - 0.53 - - 89 - - - - - - - - 230 313 3460 3.6 1 - - 50 - - - - - - - B - - - - - - - - - - - - - - - - - - - - -
min 1~230 125 - 1110 1955 47 - IP X4 7.8 - - 50/60 - - - - - - - - - - - - - - - - - - - - - - - - - - - 100 - plastic - - for round air ducts mixed-flow - Inline - - - 0.54 60 - - - - To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor).
max 1~230 177 - 1400 2440 55 - IP X4 7.8 - - 50/60 - - - - - - - - - - - - - - - - - - - - - - - - - - - 315 - plastic - - for round air ducts mixed-flow - Inline - - - 0.79 60 - - - - To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor).
speed 1 - - - - - - - - - - - - - 220-240 0.12 890 35 - - IP 55 26.6 - - - - - - 50 - 50 12 220В / 50Гц 80 - - - - - - 80 - - - - - centrifugal exhaust wall mounting , ceiling mounting - - - - - - 4×1.5 - - -
speed 2 - - - - - - - - - - - - - 220-240 0.14 1350 63 - - IP 55 30 - - - - - - 50 - 50 17 220В / 50Гц 80 - - - - - - 80 - - - - - centrifugal exhaust wall mounting , ceiling mounting - - - - - - 4×1.5 - - -
speed 3 - - - - - - - - - - - - - 220-240 0.18 1830 102 - - IP 55 35.2 - - - - - - 50 - 50 27 220В / 50Гц 80 - - - - - - 80 - - - - - centrifugal exhaust wall mounting , ceiling mounting - - - - - - 4×1.5 - - -
- - - - - - - - - - - - - - 220-240 0.1 2300 116 - 0.69 IP 24 36 - - - - - - 50/60 - - 16 - 100 - - - - - 220-240V / 50-60Hz 100 - - - - - axial exhaust wall mounting , ceiling mounting - - - - - - - - - -