VENTS 100 S turbo (220/60)
- Description
- Characteristics
- Downloads
- Options
- Dimensions
- Additional diagrams
Description
Description
APPLICATION | |
|
|
DESIGN | |
|
|
MOTOR | |
|
|
CONTROL | |
Manual:
|
Automatic:
|
MOUNTING FEATURES | |
|
|
MOUNTING EXAMPLE | |
Characteristics
Characteristics
Parameter | Value | Measurement unit |
---|---|---|
Engine Type | 220V / 60Hz | - |
Voltage | 220 | V |
Frequency | 60 | Hz |
Power consumption | 13.19 | W |
Air capacity | 102 | m³/h |
Pressure | 45 | Pa |
Current | 0.093 | A |
Sound pressure level at 3 m | 33 | dBА |
Spigot size | 100 | mm |
Design | axial | - |
Duct diameter | 100 | mm |
IP Code | IP 34 | - |
Type | exhaust | - |
Mounting | wall mounting , ceiling mounting | - |
Files archieve
Downloads
Modifications
Modifications
Modification name | High-powered fan | |
---|---|---|
VENTS 100 S turbo (220/60) |
|
Dimensions
Characteristics
Parameter | Value | Measurement unit |
---|---|---|
Ø D | 100 | mm |
B | 150 | mm |
H | 120 | mm |
L | 108 | mm |
L1 | 12 | mm |
Additional diagrams
Additional diagrams
Designation key
Designation key
PICTURE SYMBOL | DESIGNATION | MODIFICATION DESCRIPTION |
S1 | Shortened flange model. | |
S К | Fan is equipped with a backdraft damper for back flow preventing. | |
S L | The motor is equipped with ball bearings for long service life (appr. 40 thousand hours) and fan mounting at any angle. The bearings are maintenance-free and contain enough grease for the entire operating period. | |
S turbo | High-powered motor. | |
S 12 | Modification with low-voltage motor. 12 V AC power supply. | |
S T | Equipped with a regulated timer with the operating time from 2 to 30 minutes. | |
S TH | Equipped with a timer with the operating time from 2 to 30 minutes and a humidity sensor with the threshold value from 60 to 90 %. | |
S V | Equipped with a pull cord switch. | |
S VТ | Equipped with a pull cord switch and a regulated timer with the operating time adjustable from 2 to 30 minutes. | |
S ВТН | Equipped with a pull cord switch, regulated timer with the operating time adjustable from 2 to 30 minutes and a humidity sensor with the operating threshold range from 60 to 90 %. |
Example of installation
Example of installation
Accessories