Characteristics
Characteristics
Parameter Value Measurement unit
Voltage 220 V
Frequency 60 Hz
Power consumption 16 W
Air capacity 161 m³/h
Current 0.1 A
RPM 2400 min-1
Sound pressure level at 3 m 34 dBА
Spigot size 120 mm
Engine Type 220V / 60Hz -
Design axial -
Duct diameter 120 mm
IP Code IP 34 -
Weight 0.74 kg
Type exhaust -
Mounting wall mounting , ceiling mounting -
Capacity diagram
Capacity diagram
  • Selection method:
  • Air flow:
  • Pressure:
Operating point
  • Air flow: --
  • Pressure: ---
Files archieve
Downloads
Modifications
Modifications
Modification name Backdraft damper
VENTS 120 LD K (220 V/60 Hz)
+
Dimensions
Characteristics
VENTS 120 LD (220 V/60 Hz)
Parameter Value Measurement unit
Ø D 120 mm
B 177 mm
H 140 mm
L 129 mm
L1 34 mm
Designation key
Designation key
PICTURE SYMBOL DESIGNATION MODIFICATION DESCRIPTION
  LDA The fan with a ground alumunium front panel.
  LDA gold The fan with a gold-tinted aluminium front panel.
  LDA chrome The fan with a mirror finish aluminium front panel.
  LD alumat The fan with a front panel painted silver (matt).
  LD alulak The fan with a front panel painted silver (gloss).
  LD1 Shortened branch pipe model.
LD K Fan is equipped with a backdraft damper for back flow preventing.
LD L The motor is equipped with ball bearings for long service life (appr. 40 thousand hours) and fan mounting at any angle. The bearings are maintenance-free and contain enough grease for the entire operating period.
LD turbo High-powered motor.
LD 12 Modification with low-voltage motor. 12 V AC power supply.
LDT Equipped with a regulated timer with the operating time from 2 to 30 minutes.
LDTH Equipped with a timer with the operating time from 2 to 30 minutes and a humidity sensor with the threshold value from 60 to 90 %.
LDV Equipped with a pull cord switch.
LDVT Equipped with a pull cord switch and a regulated timer with the operating time adjustable from 2 to 30 minutes.