VENTS iFan CELSIUS


Maximum capacity - 133 m3/h.

3D model
Gallery
  • Description
  • Characteristics
  • Downloads
  • Certificates
  • Dimensions
Description
Description
APPLICATION  
  • Being equipped with a temperature sensor VENTS iFan CELSIUS can detect a heat level increase and ensure efficient ventilation by balancing warm air streams among spaces. The integrated automatic control unit enables finetuning the fan modes by selecting appropriate temperature for a comfortable microclimate in flats and private residences.
  • VENTS iFan CELSIUS installed in a well-heated space can make a good use of its heat to warm up the air in a connected space heated to a lower temperature or unheated at all.
DESIGN  
  • The internal multi-function panel with indicator lights enables convenient setup of all the intelligent functions of VENTS iFan CELSIUS.

     

     

     

     

  • VENTS iFan CELSIUS received a unique purpose-designed impeller which helps reduce the noise during the fan operation to a bare minimum.

 

  • The fan is supplied with two interchangeable spigots to integrate VENTS iFan CELSIUS into Ø100 and Ø125 mm air ducts.

 

  • VENTS iFan CELSIUS benefits from a unique 3D casing design resulting in a smooth and streamlined look. The standard plain white front panel with a white grille can be replaced with any of the seven colourful extra panels with a silver grille.

     

  • The motor and impeller assembly can be easily removed from the casing without any special tools for convenient cleaning.

 

  • The remote controller enables setup and control of all the VENTS iFan CELSIUS functions from a distance.
     
     
FEATURES
 
  • The intellectual automatic control unit enables user-defined scenarios for VENTS iFan CELSIUS automatic operation with a preset temperature or external switch control. Alternatively the unit can be controlled via the remote controller.
  • VENTS iFan CELSIUS are featured with an exclusive impeller and face panel design for a stylish statement. Seven decorative front panels are available for a truly individual look (purchased separately).
  • VENTS iFan CELSIUS has gone on a power diet as it only requires 3.8 W to deliver up 133 m3/h of air flow. The fan efficiently distributes warm air among spaces to help cut down your monthly heating bill.
  • A specially designed fan casing enables both horizontal and vertical installation. The VENTS iFan CELSIUS casing merely measures 29 mm deep without the spigots.
  • A special vibration mount and an thoroughly tested aerodynamic impeller profile result in outstanding noise levels of VENTS iFan CELSIUS − only 21 dB(A).
  • The use of a static power supply unit with a wide input voltage range of 100-240 V (50-60 Hz) ensures failsafe operation of the fan in power grids with less than ideal supply standards.
OPERATION MODES  
  • The remote controller enables setup and control of all the VENTS iFan CELSIUS functions from a distance.

 TEMP. MODE / WARM AIR EXTRACTION MODE CONTROL

  • Warm Air Extraction Mode Selection − Silentor Мaхaccording to the preset temperature set point.
    Silent − Active response to a temperature increase, air capacity up to 83 m3/h. 
    Max − Active response to a temperature increase, air capacity up to 133 m3/h. Upon crossing the set temperature point the fan will switch to high speed to extract excessive heat. After the temperature on the premises drops 2 °C below the pre-set threshold the fan will revert to the initial mode.

 TIMER / FAN TURN-OFF / TURN-ON DELAY CONTROL

  • Turn-on and turn-off delay time setup upon receiving an external switch signal. 
    Setup of the high speed turn-on delay for 0, 2 or 5 minutes (in combination with the SWITCH DELAY button); 
    Setup of the turn-off delay time to complete the air extraction − 5, 15 or 30 minutes.

 SPEED / FAN SPEED CONTROL / TEMPERATURE THRESHOLD SETUP

  • Setup of the fan speed in Silent mode using the SPEED «+»and SPEED «-» buttons. Setup of the fan speed in Max mode using the SPEED «+» and SPEED «-» in combination with the MODE button. 
    Setup of the temperature set point for the fan switching to high speed and back using the SPEED «+» and SPEED «-» buttons in combination with the TEMPERATURE button. The available temperatures range from 18 to 36 °C. 
    The default temperature value is 24 °C.

 STATUS / FAN OPERATION MODE INDICATION 

  • The indicator glows green −the fan is engaged by the external switch actuation.
    The indicator blinks green every 2 seconds − the fan is on standby.
    The indicator glows red − the fan is running in the 24 HOURS mode. 
    The indicator blinks red every 2 seconds − the fan is running in the warm air extraction mode.
    The indicator alternatively blinks green and red − the fan is running in the interval ventilation air supply mode.
    The indicator blinks red twice every second − the fan is completing the turn-on delay.

 24 HOURS / 24-HOUR PERMANENT AIR SUPPLY MODE

  • The activates the constant air supply mode at the minimum speed of 33 m3/h (Ø100 mm) or 40 m3/h (Ø125 mm) until the temperature sensor or external switch actuation. 
    The 24 HOURS mode is disabled by default.

 INTERVAL VENTILATION

  • After each 15 hours of idling the fan activates automatically and supplies air to the premises for 2 hours at the flow rate of 72 m3/h (Ø100 mm) or 83 m3/h (Ø125 mm). The fan reverts to the previous operation mode upon receiving a signal from the temperature sensor or the external switch actuation.

 PAUSE / TEMPORARY FAN INTERRUPTION 

  • The PAUSE function is only accessible via the remote controller. Pressing the PAUSE button interrupts the fan operation for 45 minutes. On elapsing of this time period or upon another pressing of the PAUSE button the fan reverts to its previous mode.
DECORATIVE FRONT PANEL COLOURS*  
Ruby Star Сhampagne Black Sapphire Melange Silver Graphite Violet Topaz

 *Decorative front panels are available upon separate order.

 

CUSTOMIZE YOUR VENTS iFan CELSIUS
 
The original VENTS iFan CELSIUS with a plain white panel and a removable white grille
Colour Decorative
Front Panel
Removable
White Grille
Removable 
Silver Grille
Colour  VENTS iFan CELSIUS with a Silver Front Panel Colour VENTS iFan CELSIUS with a White Front Panel Plain White VENTS iFan CELSIUS with a Silver Front Panel
 
 
INSTALLATION

 

Characteristics
Characteristics
Parameter iFan CELSIUS
(Ø100) 24 hours
iFan CELSIUS
(Ø100) Max
iFan CELSIUS
(Ø125) 24 hours
iFan CELSIUS
(Ø125) Silent
iFan CELSIUS
(Ø125) Max
iFan CELSIUS
(Ø100) Silent
Measurement unit
Sound pressure level at 3 m Sound pressure level at 3 m 17 31 17 21 32 22 dBА
Voltage 100-240 100-240 100-240 100-240 100-240 100-240 V
Air flow factory settings Air flow factory settings 33 82 40 83 97 72 -
Frequency 50/60 50/60 50/60 50/60 50/60 50/60 Hz
Air capacity 33 106 40 83 133 72 m³/h
Regulation range - 72...106 - 40...83 83...133 33...72 m³/h
Spigot size 100 100 125 125 125 100 mm
Design axial axial axial axial axial axial -
Duct diameter 100 100 125 125 125 100 mm
IP Code IP 44 IP 44 IP 44 IP 44 IP 44 IP 44 -
Type exhaust exhaust exhaust exhaust exhaust exhaust -
Mounting wall mounting, ceiling mounting wall mounting, ceiling mounting wall mounting, ceiling mounting wall mounting, ceiling mounting wall mounting, ceiling mounting wall mounting, ceiling mounting -
Files archieve
Downloads
Select document type
  • Advertising and printing products
  • Certificates
  • Technical documentation
Name
Download high quality image "VENTS iFan CELSIUS" (psd 1.81Mb)
Catalogue "VENTS iFan CELSIUS" (pdf 3.37Mb)
Download image "VENTS iFan CELSIUS" for your website (png 403.47Kb)
"VENTS iFan CELSIUS" user's manual 2012 (V01EN-(iFan Celsius)-02) (pdf 5.78Mb)
Certificates
Certificates
<p>
	Mark of conformity to the European Quality Standards and Electrical Safety issued by Association for Technical Inspection (Technischer Überwachungsverein, Germany).</p>

Mark of conformity to the European Quality Standards and Electrical Safety issued by Association for Technical Inspection (Technischer Überwachungsverein, Germany).

<p>
	Mark of conformity to the Ukrainian Quality Standards and electrical safety issued by UkrTEST.</p>

Mark of conformity to the Ukrainian Quality Standards and electrical safety issued by UkrTEST.

<p>
	Insulation class: double insulation.</p>

Insulation class: double insulation.

<p>
	Equipment protection rating.</p>

Equipment protection rating.

CE mark means that the equipment is produced in compliance with the quality and safety standards provided by EU regulations for the given product type (marked by manufacturer). CE mark means that the equipment is produced in compliance with the quality and safety standards provided by EU regulations for the given product type (marked by manufacturer).
<p>The EurAsian Conformity mark is a certification mark to indicate that the products conform to all technical regulations of the Eurasian Customs Union.</p>

The EurAsian Conformity mark is a certification mark to indicate that the products conform to all technical regulations of the Eurasian Customs Union.

Dimensions
Characteristics
VENTS iFan CELSIUS
Parameter Value Measurement unit
Ø D 100/125 mm
B 152 mm
H 206 mm
L 57 mm
L1 29 mm
Share your opinion