Login

Privacy Policy (GDPR)
Authorization
Not registered yet? Take advantages of registration:
Products saving in a binding to the projects
Product consultation from our experts - Online
Registration
Signup
By using this form, you confirm that you have read the site terms of use Terms of use and completely accept the terms of use

Series VENTS Quiet-Mild Duo

Series VENTS Quiet-Mild Duo
Two-speed axial low-noise and low energy fans for exhaust ventilation with air flow up to 170 m³/h.
Model features
  • Extract mode
  • Domestic fans
  • Axial fan
3D model
Gallery
  • Description
  • Modifications
  • Capacity diagram
  • Downloads
  • Legend
Description
Description
APPLICATION  
  • Innovative exhaust fan with stylish design.
  • Ideal for intermittent or continuous ventilation of bathroom, showers, kitchens and other utility spaces.
  • Two-speed ventilation up to 170 m³/h.
  • Permanent low-speed operation mode ensures continuous minimum air exchange in the room.
  • Ventilation shaft mounting or connection to Ø 100 and 125 mm air ducts.
COLOUR MODIFICATIONS  
DESIGN  
  • The casing and the impeller of the fan are made of high-quality durable plastic, UV resistant.
  • The aerodynamic design of the impeller ensures high air flow and low noise level.
  • The compact design enables wall and ceiling installation.
  • A shortened spigot for mounting into a ventilation shaft or direct connection to Ø 100 mm and 125 mm air ducts.
  • The fan is equipped with a specially designed backdraft damper to prevent back flow and heat losses during the fan standby.
  • The fan outlet pipe incorporates specially designed air rectifiers to reduce air turbulence, noise level and increase air pressure.
  • High ingress protection rating makes the fan the ideal bathroom ventilation solution. The electronic components are protected with tight covers.
MOTOR  
  • Low energy demand from 4 W due to a new two-speed high-efficient motor on ball bearings.
  • Maintenance-free bearings contain enough grease for 40 000 hrs continuous operation.
  • The motor on special anti-vibration dampers for vibration absorbing and silent operation.
  • The motor is equipped with overheating protection.
OPERATION MODES OF THE FANS WITH MODIFICATIONS T, TH:

The fan operates at Speed 1 by default. The fan switches to Speed 2 when the switch is closed or the humidity sensor is activated.

CONTROL  

Manual:

  • The fan is controlled by a room light switch. It is not included in the delivery set.
  • The fan is controlled with a built-in pull cord switch "V". This option is not applicable for ceiling mounting.
  • Speed control with a thyristor speed controller or a P2-1-300 speed switch, see Electrical Accessories. Several fans may be connected to the same controller. Speed controllers cannot be connected to the T and TH fan modifications.

Automatic:

  • Speed control with a BU-1-60 electronic control unit, refer to Electric accessories. The control unit is supplied separately.
  • By the timer T. The built-in turn-off delay timer enables fan operation at high speed within 2 to 30 minutes after the fan switching of.
  • By the humidity sensor and timer TH. If the humidity level in the room exceeds the sensor threshold within 60-90 %, the fan switches automatically to a high speed and operates until the humidity level drops to the standard level. After that, the fan continues operating within the set time period and then reverts to the standard operation mode with the low speed.
MOUNTING FEATURES  
  • The fan is mounted directly into the ventilation shaft.
  • Flexible duct connection is recommended in case of the remote ventilation shaft location. The air duct is connected to the fan exhaust spigot through a clamp.
  • Fixing to wall with screws.
Modifications
Backdraft damper
Pull-cord switch
Timer
Interval timer
Humidity sensor
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
+
+
+
+
+
+
+
+
Capacity diagram
Capacity diagram
  • Selection method:
  • Air flow:
  • Pressure:
Operating point
  • Air flow: --
  • Pressure: ---
Downloads
Downloads
Select document type
  • Advertising and printing products
  • Certificates
  • Technical documentation
Name
"VENTS Quiet-Mild Duo" product description 06-2018 (pdf 2.49Mb)
Download image "VENTS Quiet-Mild Duo" for your website (png 676.89Kb)
Download high quality image "VENTS Quiet-Mild Duo" (psd 2.61Mb)
Download image "VENTS Quiet-Mild Duo Red" for your website (png 687.6Kb)
Download high quality image "VENTS Quiet-Mild Duo Red" (psd 2Mb)
Download image "VENTS Quiet-Mild Duo Vintage" for your website (png 516.08Kb)
Download high quality image "VENTS Quiet-Mild Duo Vintage" (psd 2.44Mb)
Download image "VENTS Quiet-Mild Duo Aluminum Lacquer" for your website (png 445.5Kb)
Download high quality image "VENTS Quiet-Mild Duo Aluminum Lacquer" (psd 2.13Mb)
Download image "VENTS Quiet-Mild Duo Chrome" for your website (png 427.33Kb)
Download high quality image "VENTS Quiet-Mild Duo Chrome" (psd 1.99Mb)
Download image "VENTS Quiet-Mild Duo Black Sapphire" for your website (png 438.67Kb)
Download high quality image "VENTS Quiet-Mild Duo Black Sapphire" (psd 2.19Mb)
"VENTS Quiet-Mild (Duo)" user’s manual 01-2019 (V167EN-03) (pdf 3.33Mb)
Legend
Legend
PICTURE SYMBOL DESIGNATION MODIFICATION DESCRIPTION
Quiet-Mild T Modification with a turn-off delay timer and an interval timer (integrated function of automatic ventilation activation). Once in 6, 14 or 24 hours the fan is switched on for up to 30 minutes to ventilate a premise with the low speed. On elapsing of the set turn-off delay time the fan switches off automatically.
Quiet-Mild TH Modification with a turn-off delay timer (delay time from 2 to 30 min) and a humidity sensor with an adjustable threshold from 60 to 90 %.
Quiet-Mild V Modification with a pull cord switch.

* VENTS Quiet-Mild 100 Duo and VENTS Quiet-Mild 125 Duo with modifications T and TH are supplied with an integrated turn-on delay timer to avoid unnecessary switching of the fan if you use your bathroom shortly and frequently.
After humidity increases or after signalling from the external switch, the fan switches to a higher speed not immediately, but after a set time period (1 min).

Share your opinion

Questionnaire
How often do you use equipment selection program?