VENTS VUT/VUE 180 P5 air handling units with heat recovery
- Description
- Modifications
- Downloads
- Designation key
- Accessories
Description
Description
DESCRIPTION |
|
- The air handling units are the fully featured ventilation units with heat recovery for air filtration, fresh air supply and stale air extract.
- The extract air heat is used for warming up of the supply air stream in the high-efficient plate heat exchanger.
|
- The units offer energy-efficient ventilation for cottages and flats and are compatible with round Ø 150 mm air ducts.
|
FILTER |
CASING |
- The built-in G4 supply filter and G4 extract filter provide air filtration.
- A F7 supply filter (specially ordered accessory) may be used for efficient supply air filtration.
|
- The casing is made of expanded polypropylene (EPP) possessing high heat- and sound-insulating properties.
|
FANS |
|
- Single-phase three-speed external rotor motors with centrifugal impellers and forward curved blades.
|
- The motors have overheating protection with automatic restart.
|
HEAT EXCHANGER |
|
- The VUT 180 P5 units are equipped with a counterflow polystyrene heat exchanger.
- In the cold season the extract air heat is transferred to the intake air stream which reduces ventilation-generated heat losses.
- This can lead to formation of condensate that is collected in a special drain pan and discharged into the sewage system.
- In the warm season the outside air heat is transferred to the exhaust air stream.
- This allows for a considerable reduction of the supply air temperature which, in its turn, reduces the air conditioning load.
|
- The VUE 180 P5 units are equipped with a counterflow heat exchanger with an enthalpy membrane at the core.
- In the cold season the extract air heat and moisture are transferred to the supply air stream through the enthalpy membrane.
- Heat recovery minimises heat losses from ventilation.
- In the warm season the outdoor air heat and moisture are transferred to the exhaust air stream through the enthalpy membrane.
- This enables considerable reduction of the supply air temperature and humidity which, in its turn, reduces the air conditioning load.
|
CONTROL AND AUTOMATION |
|
- The unit is equipped with integrated control system.
- It can be supplied either with the mechanical threespeed speed controller P3-1-300 or the sensor threespeed speed controller SP3-1, power cable with Europlug XP mains plug.
- The service side of the unit has a removable inspection door with hand screws to enable heat exchanger and filter cleaning and replacement.
- The control unit is located inside of the unit casing.
- The power cable and the ground cable are connected to the control unit via the cable glands on the side on the unit.
|
|
FREEZE PROTECTION |
INSTALLATION |
- The freeze protection is realized by means of shutdown the supply fan as follows: in case of freezing danger communicated by the temperature sensor the supply fan is turned off to let the heat exchanger defrosting with the extract air heat.
- After freezing danger is no longer imminent, the unit reverts to the standard operation mode.
|
- The unit is designed for suspended ceiling, wall horizontal or vertical installation using the fixing brackets.
- The mounting position of the unit must provide service access for maintenance and repair
|
UNIT DESIGN |
|
|
APPLICATION OPTIONS |
|
|
Designation key
Designation key
Series |
Rated air flow [m³/h] |
Mounting type |
Casing design |
Control |
VUT: ventilation with heat recovery VUE: ventilation with energy recovery |
180 |
P: suspended |
5: expanded polypropylene |
А3: P3-1-300 speed controller А4: SP3-1 speed controller |
Accessories
Accessories
Model |
G4 panel supply filter |
F7 panel supply filter |
|
|
VUT 180 P5 |
SF 214 x 186 х 18 G4 |
SF 214 x 186 x 48 F7 |
VUE 180 P5 |