Found 41 series
Roof-mounted smoke removal fans VENTS VKDV
  • Extract mode
  • Roof fan
  • Smoke extraction ventilation
More
Roof-mounted centrifugal fan for smoke extraction with vertical air discharge.
Duct smoke extraction fan VENTS VKPD
  • For rectangular ducts
  • Industrial and commercial fans
  • Smoke extraction ventilation
More
Duct smoke extraction fan. Air flow – up to 28 500 m³/h.
Roof-mounted smoke removal fans VENTS VKDH
  • Extract mode
  • Roof fan
  • Smoke extraction ventilation
More
Roof-mounted centrifugal fan for smoke extraction with horizontal air discharge.

Roof-mounted smoke extraction fans VENTS VKDV-K2
  • Extract mode
  • Roof fan
  • Smoke extraction ventilation
More
Roof-mounted centrifugal fan for smoke extraction with vertical air discharge.
Air flow – up to 86 500 m³/h.
VENTS VPVO series
  • Axial inline fan
  • Axial fan
  • Smoke extraction ventilation
More
Medium pressure axial fans with air capacity up to 120 000 m³/h.
VENTS VDO series
  • Axial inline fan
  • Axial fan
  • Smoke extraction ventilation
More
Axial smoke extraction fans with air capacity up to 114 000 m³/h and fire resistance rating: 300 °C/2 hours; 400 °C/2 hours.

VENTS VPVO/VDO 1400 and 1600 mm series
  • Axial inline fan
  • Axial fan
  • Smoke extraction ventilation
More
Axial pressurization and smoke extraction fans.
Standard sizes 1400 and 1600 mm.
VENTS JAF jet axial fans
  • Noise isolation
  • Axial fan
  • Smoke extraction ventilation
More
Axial jet fans for ventilation of covered parking. Temperatures of the transported medium: in continuous operation up to +55 °C in smoke extraction mode: 300 °C – 2 hrs; 400 °C – 2 hrs. Functionality. Power. Efficiency.
VENTS ICF induction centrifugal fans
  • Centrifugal fan
  • Double-speed
  • Smoke extraction ventilation
More
Induction centrifugal fans of underground parkings.
Temperatures of the transported medium: in continuous operation up to +55 °C; in smoke extraction mode: 300 °C/2 h; 400 °C/2 h.
Compactness. Power. Efficiency.

VENTS JAF (60 Hz) axial jet fans
  • Noise isolation
  • Axial fan
  • Smoke extraction ventilation
More
Axial jet fans for ventilation of parkings.
Transported air temperature in continuous mode up to +55 °C, in smoke extraction mode: 300 °C/2 h, 400 °C/2 h.
Functionality. Power. Efficiency.
KPD series
  • For household application
  • For commercial buildings
  • For industrial buildings
More
Normally closed single louvre fire safety dampers, fire resistance rating of 180 minutes at smoke temperature of 600 °C.
VENTS ICF (60 Hz) induction centrifugal fans
  • Centrifugal fan
  • Double-speed
  • Smoke extraction ventilation
More
Induction centrifugal fans for ventilation of parkings.
Transported air temperature in continuous mode up to +55 °C, in smoke extraction mode: 300-400 °C/2 h.
Compactness. Power. Efficiency.

KRD series
  • For commercial buildings
  • For industrial buildings
  • Smoke extraction ventilation
More
KRD excess pressure relief valves are used in smoke protection, ventilation and air conditioning systems to regulate the pressure difference between adjacent rooms.
KPDU series
  • For household application
  • For commercial buildings
  • For industrial buildings
More
Normally closed multiple-louvre fire safety dampers, fire resistance rating of 180 minutes at smoke temperature of 600 °C.
KRDP series
  • For commercial buildings
  • For industrial buildings
  • Smoke extraction ventilation
More
KRDP excess pressure valves are used to regulate pressure difference in fire protection ventilation systems.

KP-1...72S series
  • For commercial buildings
  • For industrial buildings
  • Smoke extraction ventilation
More
Normally open fire-resisting duct damper with mechanical drive mechanism.
VENTS KP-1...PKP, KP-1...PVP, KP-1...PSP series
  • For commercial buildings
  • For industrial buildings
  • Smoke extraction ventilation
More
Normally open fire-resisting duct damper with electric drive mechanism.
VENTS KP-2...72S series
  • For commercial buildings
  • For industrial buildings
  • Smoke extraction ventilation
More
Normally open fire-resisting duct damper with mechanical drive mechanism.

VENTS KP-2...PKP, KP-2...PVP, KP-2...PSP series
  • For commercial buildings
  • For industrial buildings
  • Smoke extraction ventilation
More
Normally open fire-resisting duct damper with electric drive mechanism.
VENTS KP-2...PKP...-1, KP-2...PVP...-1, KP-2...PSP...-1 series
  • For commercial buildings
  • For industrial buildings
  • Smoke extraction ventilation
More
Normally open fire-resisting duct damper with simplified design with electric drive mechanism.
VENTS PL-10-1A series
  • For commercial buildings
  • For industrial buildings
  • Smoke extraction ventilation
More
Normally open fire-resisting duct damper with thermal fuse and return spring.

VENTS PL-10-PKP, PL-10-PVP, PL-10-PSP series
  • For commercial buildings
  • For industrial buildings
  • Smoke extraction ventilation
More
Normally open fire-resisting duct damper with electric actuator, return spring and thermoelectric breaker.
O-VO carrier
  • Ventilation ducts and fittings
More
Carriers for mounting the fans to the floor, walls or ceiling.
F-VO flange
  • Ventilation ducts and fittings
More
Flanges enable attaching round ducts of appropriate size to the fan.

VVGF-VO, VVGF-VO...400/2 flexible joint
  • Ventilation ducts and fittings
More
Flexible joints cancel out any potential vibrations transmitted by the fans or air handling units to the air ducting as well as partially compensate for the air duct assembly deformations caused by temperature variation.
Z-VO hood
  • Ventilation accessories
More
Hoods ensure trouble-free operation of fans on rooftops.
PK-VO roof adapter
  • Ventilation ducts and fittings
More
Roof adapters are used for mounting fans on rooftops.

RD1 smoke exhaust grille
  • Ventilation accessories
  • Air distribution
  • Smoke extraction ventilation
More
The KPD/KPDU smoke exhaust dampers and the KP-1, KP-2 wall-mounted fire-resisting dampers (1 flange) can be additionally equipped with a smoke exhaust grille.
RZ protective grille
  • Ventilation accessories
  • Air distribution
  • Smoke extraction ventilation
More
The KPD/KPDU smoke exhaust dampers and the KP-1, KP-2 wall-mounted fire-resisting dampers (1 flange) can be additionally equipped with a protective grille.
SM-VO mounting curb
  • Ventilation accessories
  • Outdoor mounting
  • Smoke extraction ventilation
More
The mounting curbs are used for mounting fans on rooftops.

VK-VO inlet cone
  • Ventilation ducts and fittings
More
The inlet cone should be installed upstream of the fan to improve the air flow parameters.
ONF/ONFS aluminium decorative grille
  • Ventilation accessories
  • Air distribution
  • Smoke extraction ventilation
More
For supply and exhaust ventilation, heating and air conditioning systems in industrial, commercial and domestic premises.
RM mounting frame
  • Ventilation accessories
  • Smoke extraction ventilation
More
The KPD/KPDU smoke exhaust dampers can be additionally equipped with a mounting frame.

Backdraft damper KOM-VO, KOM-VO...400/2
  • For round ducts
  • Backdraft damper
  • Smoke extraction ventilation
More
The backdraft damper with spring-loaded blades is used for shutoff of air flow in the air ducts and prevention of air backdraft during standstill of ventilation equipment.
Backdraft damper KOM1-VO
  • For round ducts
  • Backdraft damper
  • Smoke extraction ventilation
More
The backdraft damper with a gravity plate is used for supply pressurisation systems and designed for shutoff of air flow during standstill of ventilation equipment.
Silencer SR
  • Noise isolation
  • For round ducts
  • Smoke extraction ventilation
More
The silencer is used for attenuation of the operation noise generated by ventilation equipment and spreaded in the air ducts.

Silencer SRV
  • Noise isolation
  • For round ducts
  • Smoke extraction ventilation
More
The silencer is used for attenuation of the operation noise generated by ventilation equipment and spreaded in the air ducts.
SZ-VO protective mesh
  • For round ducts
  • Ventilation accessories
  • Smoke extraction ventilation
More
Protective mesh protects the fans against ingress of foreign objects.
VVCp-VO spring-loaded anti-vibration mount
  • Ventilation accessories
More
The spring-loaded anti-vibration mounts are used for attenuation of noise and vibration generated by ventilation equipment.

VVCr-VO rubber anti-vibration mount
  • Ventilation accessories
More
The rubber anti-vibration mounts are used for attenuation of noise and vibration generated by ventilation equipment.
Roof-mounted fan for fireplaces VENTS VKT
  • Extract mode
  • Roof fan
  • Smoke extraction ventilation
More
Roof exhaust gas extraction booster fan for fireplaces. Air flow up to 1000 m³/h.