Roof-mounted smoke removal fans VENTS VKDV
Roof-mounted centrifugal fan for smoke extraction with vertical air discharge.
Roof-mounted smoke removal fans VENTS VKDH
Roof-mounted centrifugal fan for smoke extraction with horizontal air discharge.
Roof-mounted smoke extraction fans VENTS VKDV-K2
Roof-mounted centrifugal fan for smoke extraction with vertical air discharge.
Air flow – up to 86 500 m³/h.
Air flow – up to 86 500 m³/h.
VENTS VDO series
Axial smoke extraction fans with air capacity up to 114 000 m³/h and fire resistance rating: 300 °C/2 hours; 400 °C/2 hours.
VENTS VPVO/VDO 1400 and 1600 mm series
Axial pressurization and smoke extraction fans.
Standard sizes 1400 and 1600 mm.
Standard sizes 1400 and 1600 mm.
VENTS JAF jet axial fans
Axial jet fans for ventilation of covered parking. Temperatures of the transported medium: in continuous operation up to +55 °C in smoke extraction mode: 300 °C – 2 hrs; 400 °C – 2 hrs. Functionality. Power. Efficiency.
VENTS ICF induction centrifugal fans
Induction centrifugal fans of underground parkings.
Temperatures of the transported medium: in continuous operation up to +55 °C; in smoke extraction mode: 300 °C/2 h; 400 °C/2 h.
Compactness. Power. Efficiency.
Temperatures of the transported medium: in continuous operation up to +55 °C; in smoke extraction mode: 300 °C/2 h; 400 °C/2 h.
Compactness. Power. Efficiency.
VENTS JAF (60 Hz) axial jet fans
Axial jet fans for ventilation of parkings.
Transported air temperature in continuous mode up to +55 °C, in smoke extraction mode: 300 °C/2 h, 400 °C/2 h.
Functionality. Power. Efficiency.
Transported air temperature in continuous mode up to +55 °C, in smoke extraction mode: 300 °C/2 h, 400 °C/2 h.
Functionality. Power. Efficiency.
KPD series
Normally closed single louvre fire safety dampers, fire resistance rating of 180 minutes at smoke temperature of 600 °C.
VENTS ICF (60 Hz) induction centrifugal fans
Induction centrifugal fans for ventilation of parkings.
Transported air temperature in continuous mode up to +55 °C, in smoke extraction mode: 300-400 °C/2 h.
Compactness. Power. Efficiency.
Transported air temperature in continuous mode up to +55 °C, in smoke extraction mode: 300-400 °C/2 h.
Compactness. Power. Efficiency.
KRD series
KRD excess pressure relief valves are used in smoke protection, ventilation and air conditioning systems to regulate the pressure difference between adjacent rooms.
KPDU series
Normally closed multiple-louvre fire safety dampers, fire resistance rating of 180 minutes at smoke temperature of 600 °C.
KRDP series
KRDP excess pressure valves are used to regulate pressure difference in fire protection ventilation systems.
VENTS KP-1...PKP, KP-1...PVP, KP-1...PSP series
Normally open fire-resisting duct damper with electric drive mechanism.
VENTS KP-2...72S series
Normally open fire-resisting duct damper with mechanical drive mechanism.
VENTS KP-2...PKP, KP-2...PVP, KP-2...PSP series
Normally open fire-resisting duct damper with electric drive mechanism.
VENTS KP-2...PKP...-1, KP-2...PVP...-1, KP-2...PSP...-1 series
Normally open fire-resisting duct damper with simplified design with electric drive mechanism.
VENTS PL-10-1A series
Normally open fire-resisting duct damper with thermal fuse and return spring.
VENTS PL-10-PKP, PL-10-PVP, PL-10-PSP series
Normally open fire-resisting duct damper with electric actuator, return spring and thermoelectric breaker.
VVGF-VO, VVGF-VO...400/2 flexible joint
Flexible joints cancel out any potential vibrations transmitted by the fans or air handling units to the air ducting as well as partially compensate for the air duct assembly deformations caused by temperature variation.
RD1 smoke exhaust grille
The KPD/KPDU smoke exhaust dampers and the KP-1, KP-2 wall-mounted fire-resisting dampers (1 flange) can be additionally equipped with a smoke exhaust grille.
RZ protective grille
The KPD/KPDU smoke exhaust dampers and the KP-1, KP-2 wall-mounted fire-resisting dampers (1 flange) can be additionally equipped with a protective grille.
VK-VO inlet cone
The inlet cone should be installed upstream of the fan to improve the air flow parameters.
ONF/ONFS aluminium decorative grille
For supply and exhaust ventilation, heating and air conditioning systems in industrial, commercial and domestic premises.
RM mounting frame
The KPD/KPDU smoke exhaust dampers can be additionally equipped with a mounting frame.
Backdraft damper KOM-VO, KOM-VO...400/2
The backdraft damper with spring-loaded blades is used for shutoff of air flow in the air ducts and prevention of air backdraft during standstill of ventilation equipment.
Backdraft damper KOM1-VO
The backdraft damper with a gravity plate is used for supply pressurisation systems and designed for shutoff of air flow during standstill of ventilation equipment.
Silencer SR
The silencer is used for attenuation of the operation noise generated by ventilation equipment and spreaded in the air ducts.
Silencer SRV
The silencer is used for attenuation of the operation noise generated by ventilation equipment and spreaded in the air ducts.
VVCp-VO spring-loaded anti-vibration mount
The spring-loaded anti-vibration mounts are used for attenuation of noise and vibration generated by ventilation equipment.
VVCr-VO rubber anti-vibration mount
The rubber anti-vibration mounts are used for attenuation of noise and vibration generated by ventilation equipment.
Roof-mounted fan for fireplaces VENTS VKT
Roof exhaust gas extraction booster fan for fireplaces. Air flow up to 1000 m³/h.