VENTS DVUT 1200 HBE EC V.2
Floor-mounted single-room air handling unit with air flow up to 1240 m³/h in a heat- and sound-insulated casing. Heat recovery efficiency up to 96 %.
- Description
- Characteristics
- Downloads
- Dimensions
- Additional characteristics
- Designation key
- Accessories
Description
Description
Characteristics
Characteristics
Parameter |
DVUT 1200 HBE EC V.2 |
Measurement unit |
---|---|---|
Phase | 3 | ˜ |
Voltage | 400 | V |
Frequency | 50/60 | Hz |
Max. unit current without electric heater | 2.3 | A |
Electric preheater power | 3150 | W |
Air capacity | 1240 | m³/h |
Maximum unit current (with an electric heater) | 12 | A |
Max. unit power without electric heater | 345 | W |
Heat recovery efficiency | 84-96 | % |
Transported air temperature | -25 ... +40 | °С |
Sound pressure level at 1 m distance | 40 | dBА |
Sound pressure level at 3 m distance | 30 | dBА |
Connected air duct diameter | 400 | mm |
Functions | Wi-Fi, Filter replacement indication, Timer, Weekly schedule, Humidity sensor, External sensor connection | - |
Heating | electric preheating | - |
Casing material | polymer coated steel | - |
Insulation | 40 mm mineral wool | - |
Filter: extract | ISO Coarse >60% (G4) | - |
Filter: supply | ISO ePM1 60% (F7) | - |
Weight | 400 | kg |
Heat exchanger type | counter-flow | - |
Heat exchanger material | polystyrene | - |
SEC Class | - | - |
Mounting | floor mounting | - |
Files archieve
Downloads
Select document type
"BMS parameter table for PCOS004850 module for DVUT units" user’s manual 07-2020 (V197-1EN-02) (pdf 71.29Kb)
Dimensions
Characteristics
Parameter | Value | Measurement unit |
---|---|---|
H | 2106 | mm |
H1 | 2000 | mm |
D | 400 | mm |
H3 | 545 | mm |
H4 | 1110 | mm |
H5 | 70 | mm |
L | 1900 | mm |
L1 | 1951 | mm |
L2 | 265 | mm |
L3 | 535 | mm |
Additional characteristics
Additional characteristics
Fresh air stream length |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Designation key
Designation key
Unit series | Rated air flow [m³/h] | Installation | Bypass | Electric heaters | Drain pump | Motor type | Modernization | Control |
DVUT – unit with plastic heat exchanger |
300; 500; 1200 |
H – floor-mounted with horizontal spigots | B – bypass damper | _ – no heater E – electric preheater E2 – electric preheater and reheater |
_ – without drain pump DN – in-built drain pump |
ЕС – synchronous motor with electronic control | V.2 – second modernized generation | А21 |
Accessories
Accessories
Name | Image | DVUT 300 HB EC A21 V.2 | DVUT 500 HB EC A21 V.2 | DVUT 1200 HB EC A21 V.2 |
Outer ventilation hood made of white coated stainless steel | NB DVUT 300 HB white | NB DVUT 500 HB white | NB DVUT 1200 HB white | |
Outer ventilation hood made of brushed stainless steel | NB DVUT 300 HB chrome | NB DVUT 500 HB chrome | NB DVUT 1200 HB chrome | |
Outer ventilation grille made of aluminium | MVMA 200 bVn Al | MVMA 250 bVn Al | MVMA 400 bVn Al | |
Extract filter ISO Coarse >60% (G4) | SF 203x308x20 G4 (2 pcs.) | SF 255x448x25 G4 (2 pcs.) | SF 450x395x48 G4 | |
Supply filter ISO ePM1 60% (F7) | SF 384x273x60 F7 | SF 449x318x60 F7 | SF 540x450x48 F7 | |
VOC sensor (0-10 V) | DPWQ30600 | |||
СО2 sensor (0-10 V) | DPWQ40200 | |||
Humidity sensor (0-10 V) | DPWС11200 | |||
CO2 sensor | CO-1 | |||
CO2 sensor | CO-2 | |||
CO2 sensor | CO2-3 | |||
Humidity sensor (NO) | HR-S | |||
Humidity sensor | HV2 | |||
Hydraulic U-trap | SG-32 | |||
Drain pump | DN-2 |
Accessories