Login

Privacy Policy (GDPR)
Authorization
Not registered yet? Take advantages of registration:
Products saving in a binding to the projects
Product consultation from our experts - Online
Registration
Signup
By using this form, you confirm that you have read the site terms of use Terms of use and completely accept the terms of use

VENTS DVUT 500 HB EC V.2


Floor-mounted single-room air handling unit with air flow up to 580 m³/h in a heat- and sound-insulated casing. Heat recovery efficiency up to 94 %.

  • Description
  • Characteristics
  • Downloads
  • Dimensions
  • Additional characteristics
  • Designation key
  • Accessories
Description
Description
DESCRIPTION  
  • The DVUT HB EC V.2 and DVUE HB EC V.2 air handling units are intended for single-room ventilation of schools, offices and other public and commercial spaces.
  • These air handling units do not require a duct system and provide a simple yet efficient ventilation solution for newly built and renovated spaces.
FEATURES  
  • Efficient supply and exhaust ventilation of individual spaces.
  • Modification with an electric preheater or reheater available.
  • Modification with an enthalpy membrane heat exchanger available.
  • Low-energy EC fans.
  • Low noise operation.
  • Simple installation.
  • Contemporary design.
OPERATING PRINCIPLE
  • Warm, stale indoor air passes through the filter and the heat exchanger and is then extracted outdoors through the wall duct by the centrifugal extract fan.
  • Cold outdoor air passes through the filters and the heat exchanger and then is supplied by means of the centrifugal supply fan.
  • The heat of extracted air is transferred to supply air by means of the heat exchanger, providing comfortable fresh air temperature and reducing costs for its heating.
CASING
  • The casing is made from high-quality polymercoated steel with internal heat and sound insulation made of mineral wool from 40 to 80 mm in thickness.
  • The contemporary design helps the units blend in nicely with a wide variety of interiors.
AIR DAMPERS
  • Supply and exhaust dampers are closed automatically while the unit is off to prevent drafts.
AIR FILTRATION
  • Exhaust cassette filter: ISO Coarse >60% (G4).
  • Supply cassette filter: ISO ePM1 60% (F7).

FANS
  • The units feature high-performance, electronically commutated (EC), external rotor motors with forward curved blades. These state-of-theart units offer excellent energy efficiency. In addition to that, EC motors combine high performance and optimum control over the entire speed range. EC motors have an excellent power efficiency (up to 90 %).
PREHEATING
  • The DVUT HBE EC V.2 and DVUT HBE2 EC V.2 units are equipped with an electric preheater to prevent heat exchanger freezing.
REHEATING
  • The DVUT HBE2 EC V.2 units are equipped with electric reheaters to raise the supply air temperature.
BYPASS
  • The units are equipped with a bypass for summer ventilation.
HEAT EXCHANGER  
  • The DVUT units feature a counter-flow heat exchanger made of polystyrene.
  • The heat of the extract air is transferred to the supply air via the heat exchanger which greatly helps reduce ventilation heat losses. This can lead to formation of condensate that is collected in a special drain pan and discharged into the sewage system.
  • In the warm season the outdoor air heat is transferred to extract air. This enables considerable reduction of the supply air temperature which reduces the air conditioning load.

  • The DVUE units are equipped with a counter-flow enthalpy heat exchanger.
  • In the cold season the extract air heat and moisture are transferred to the supply air stream through the enthalpy membrane. Heat recovery minimises heat losses from ventilation.
  • In the warm season the outdoor air heat and moisture are transferred to the extract air stream through the enthalpy membrane. This enables considerable reduction of the supply air temperature and humidity, which reduces the air conditioning load.

UNIT CONTROL AND OPERATION  

Freeze protection

  • There are two methods of protecting the heat exchanger against freezing in cold conditions.
  • In units without an electric preheater the supply fan is shut down automatically, using the feedback from the extract air temperature sensor, to let the warm extract air thaw the heat exchanger. The supply fan then re-activates and the unit reverts to normal operation.
  • In units with an electric preheater the supply air is warmed up before entering the heat exchanger which prevents freezing. This method ensures a continuous balanced air exchange.

Control

  • The units DVUT/DVUE HB EC V.2 A21 are equipped with an in-built control system. An A21 controller allows integrating the unit into the Smart Home system or BMS (Building Management Systems). Remote control panel is not included in the delivery set and is available as specially ordered accessory. The unit is controlled by the Vents Home application on the mobile device. The application is available for download at App Store, Play Market or via the QR code.
   
Function А21
Wired remote control panel Option (A22)
Wired remote LCD control panel Option (A25)
Wireless remote control panel Option (A22 Wi-Fi)
BMS RS-485
Wi-Fi
Ethernet
MODBUS (RTU, TCP)
Vents Cloud Server +
Control by a mobile application via Wi-Fi +
Freeze protection +
Bypass control Auto + manual
Weekly schedule operation +
Filter maintenance warning According to filter timer
According to pressure switch of filter clogging
Alarm indication +
Speed selection +
Timer +
RH% sensor Option
CO2 sensor Option
VOC sensor Option
PM2.5 sensor Option
Boost mode +
Fireplace mode +
Preheating Option
Reheating Option
Cooler connection Option
Fire alarm sensor connection Option
Supply air temperature control +
Characteristics
Characteristics
Parameter DVUT 500 HB EC V.2
Measurement unit
Phase 1 ˜
Voltage 230 V
Frequency 50/60 Hz
Max. unit current without electric heater 2.5 A
Air capacity 580 m³/h
Maximum unit current (with an electric heater) 2.5 A
Max. unit power without electric heater 370 W
Heat recovery efficiency 75-94 %
Transported air temperature -25 ... +40 °С
Sound pressure level at 1 m distance 47 dBА
Sound pressure level at 3 m distance 38 dBА
Connected air duct diameter Connected air duct diameter 250 mm
Functions Wi-Fi, Filter replacement indication, Timer, Weekly schedule, External sensor connection -
Heating without heating -
Casing material polymer coated steel -
Insulation 40 mm mineral wool -
Filter: extract ISO Coarse >60% (G4)x2 -
Filter: supply ISO ePM1 60% (F7) -
Weight 139 kg
Heat exchanger type counter-flow -
Heat exchanger material polystyrene -
SEC Class A -
Mounting floor mounting -
Files archieve
Downloads
Select document type
  • Advertising and printing products
  • Certificates
  • Technical documentation
Name
"DVUT 1200 HB EC V.2" user's manual 05-2023 (V142-1EN-03) (pdf 3.55Mb)
"NB DVUT HB" installation instruction 11-2020 (V113-14EN-01) (pdf 1.12Mb)
"DVUT HB EC and DVUE HB EC V.2" user's manual 03-2023 (V142EN-08) (pdf 3.33Mb)
"Wireless control system A21" user’s manual 02-2023 (V55-8EN-05) (pdf 491.75Kb)
"Single-room ventilation for schools and public spaces" catalog 2023 (pdf 4.68Mb)
"BMS parameter table for PCOS004850 module for DVUT units" user’s manual 07-2020 (V197-1EN-02) (pdf 71.29Kb)
Download high quality image "DVUT HB EC and DVUE HB EC V.2" (psd 984.34Kb)
Download image "DVUT HB EC and DVUE HB EC V.2" for your website (png 207.51Kb)
Download high quality image "DVUT 1200 HB EC V.2" (psd 27.25Mb)
Download image "DVUT 1200 HB EC V.2" for your website (png 314.17Kb)
Dimensions
Characteristics
VENTS DVUT 500 HB EC V.2
Parameter Value Measurement unit
W 750 mm
W1 350 mm
W2 200 mm
L 535 mm
L1 585 mm
H 2170 mm
H1 1865 mm
H2 305 mm
D 250 mm
* The unit height may be adjusted by means of levelling feet. -
Additional characteristics
Additional characteristics


Point Power [W] Sound pressure level at 3 m (1m) [dBA]
1 236 37 (47)
2 236 -
3 234 35 (45)
4 234 28 (37)
5 80 28 (39)
6 78 -
7 76 -
8 75 -
9 21 17 (27)
10 19 -
11 20 -

 


Fresh air stream length
Sound power level,
A-weighted
Total Octave frequency band [Hz] LpA, 3 m LpA, 1 m 
200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000 6300 8000 10000
LwA to environment at point 1 [dBA] 57 47 52 51 48 47 44 45 45 44 46 48 45 38 30 27 25 26 27 38 47
LwA to environment at point 5 [dBA] 49 44 37 36 42 38 38 37 38 37 39 41 37 29 24 23 22 25 26 28 39
LwA to environment at point 9 [dBA] 37 28 27 26 31 29 28 28 29 27 27 28 25 21 20 21 22 25 27 17 27
LwA to environment at point 3 [dBA] 55 47 46 42 47 46 43 43 43 43 43 45 42 35 29 27 24 26 27 35 45
LwA to environment at point 4 [dBA] 47 49 48 49 52 51 50 50 49 48 46 46 44 38 33 30 27 28 28 28 37
Designation key
Designation key
Unit series Rated air flow [m³/h] Installation Bypass Electric heaters Drain pump Motor type Modernization Control

DVUT – unit with plastic heat exchanger

DVUE – unit with enthalpy heat exchanger

300;
500;
1200
H – floor-mounted with horizontal spigots B – bypass damper _ – no heater

E – electric preheater

E2 – electric preheater and reheater
_ – without drain pump

DN – in-built drain pump
ЕС – synchronous motor with electronic control V.2 – second modernized generation А21
Accessories
Accessories
Name Image DVUT 300 HB EC A21 V.2 DVUT 500 HB EC A21 V.2 DVUT 1200 HB EC A21 V.2
Outer ventilation hood made of white coated stainless steel NB DVUT 300 HB white NB DVUT 500 HB white NB DVUT 1200 HB white
Outer ventilation hood made of brushed stainless steel NB DVUT 300 HB chrome NB DVUT 500 HB chrome NB DVUT 1200 HB chrome
Outer ventilation grille made of aluminium MVMA 200 bVn Al MVMA 250 bVn Al MVMA 400 bVn Al
Extract filter ISO Coarse >60% (G4) SF 203x308x20 G4 (2 pcs.) SF 255x448x25 G4 (2 pcs.) SF 450x395x48 G4
Supply filter ISO ePM1 60% (F7) SF 384x273x60 F7 SF 449x318x60 F7 SF 540x450x48 F7
VOC sensor (0-10 V) DPWQ30600
СО2 sensor (0-10 V) DPWQ40200
Humidity sensor (0-10 V) DPWС11200
CO2 sensor CO-1
CO2 sensor CO-2
CO2 sensor   CO2-3
Humidity sensor (NO) HR-S
Humidity sensor HV2
Hydraulic U-trap SG-32
Drain pump DN-2
Share your opinion

Questionnaire
Basic parameter for domestic fan selection