VENTS KSB 250
- Description
- Characteristics
- Downloads
- Dimensions
- Additional diagrams
- Legend
APPLICATIONS | |
|
|
DESIGN | |
|
|
MOTOR | |
|
|
SPEED CONTROL | |
|
|
MOUNTING | |
|
|
The fan with electronic temperature and control module (U option)
|
|
|
|
|
|
Control logic of the fan with the electronic temperature and speed control module
|
|
|
|
There are two switch delay patterns for various cases: | |
|
|
Example for temperature sensor delay: | Example for timer delay: |
|
|
|
|
↓ | ↓ |
|
|
↓ | |
|
|
↓ | ↓ |
|
|
↓ | ↓ |
|
|
↓ | |
|
|
↓ | |
|
|
↓ | |
|
|
|
Parameter |
KSB 250 50 Hz |
KSB 250 60 Hz |
Measurement unit |
---|---|---|---|
Phase | 1 | 1 | ˜ |
Voltage | 230 | 230 | V |
Frequency | 50 | 60 | Hz |
Sound pressure level at 3 m distance | 41 | 43 | dBА |
Power consumption | 198 | 238 | W |
Maximum air capacity | 1300 | 1315 | m³/h |
RPM | 2420 | 2730 | min-1 |
Current | 0.87 | 1.04 | A |
Max. transported air temperature | -25...+55 | -25...+55 | °С |
Protection rating | IP X4 | IP X4 | - |
Design | centrifugal | centrifugal | - |
Weight | 12.5 | 12.5 | kg |
Duct diameter | 250 | 250 | mm |
Sound- and heat-insulated casing | yes | yes | - |
Casing material | galvanized steel | galvanized steel | - |
SEC Class | - | - | - |
Duct | for round air ducts | for round air ducts | - |
Type | supply and exhaust | supply and exhaust | - |
Mounting | Inline | Inline | - |
Parameter | Value | Measurement unit |
---|---|---|
∅D | 249 | mm |
B1 | 368 | mm |
H | 287 | mm |
B | 432 | mm |
L | 588 | mm |
L1 | 506 | mm |
L2 | 480 | mm |
Sound-power level | Octave-frequency band [Hz] | |||||||||||||||||||
Hz | General | 63 | 125 | 250 | 500 | 1000 | 2000 | 4000 | 8000 | |||||||||||
LwA to inlet | dBA | 59 | 44 | 45 | 54 | 51 | 47 | 45 | 45 | 38 | ||||||||||
LwA to outlet | dBA | 74 | 51 | 51 | 62 | 70 | 67 | 64 | 61 | 55 | ||||||||||
LwA to environment | dBA | 46 | 33 | 36 | 41 | 42 | 30 | 26 | 23 | 27 |
Series | Spigot diameter | Options |
VENTS KSB |
100; 125; 150; 160; 200; 250; 315 | R - power cord with IEC C14 electric plug; S - high-powered motor; M – anti-vibration mount; U - speed controller with electronic thermostat and temperature sensor integrated into the air duct. Equipped with power cord and IEC C14 electric plug. Temperature-based operation logic; Un -speed controller with electronic thermostat and external temperature sensor fixed on 4 m cable. Equipped with power cord and IEC C14 electric plug. Temperature-based operation logic; U1 - speed controller with electronic thermostat and temperature sensor integrated into the air duct. Equipped with power cord and IEC C14 electric plug. Timer-based operation logic; U1n - speed controller with electronic thermostat and external temperature sensor fixed on 4 m cable. Equipped with power cord and IEC C14 electric plug. Timer-based operation logic. |