Login

Privacy Policy (GDPR)
Authorization
Not registered yet? Take advantages of registration:
Products saving in a binding to the projects
Product consultation from our experts - Online
Registration
Signup
By using this form, you confirm that you have read the site terms of use Terms of use and completely accept the terms of use

VENTS Flip series

VENTS Flip series

Low-noise and low-power extract axial fan with air capacity up to 85 m³/h. Mounting into ventilation shafts or connection to Ø 100 mm air ducts.

Model features
  • Backdraft damper
  • Axial fan
  • Timer
  • Description
  • Modifications
  • Capacity diagram
  • Downloads
  • Certificates
  • Legend
  • Video
Description
Description
APPLICATIONS
  • Permanent or intermittent extract ventilation of shower rooms, bathrooms, kitchens and other residential premises.
  • Ventilation of premises with high requirements to noise level.
  • Mounting into ventilation shafts or connection to Ø 100 mm air ducts.
DESIGN
  • Modern design and aesthetic look.
  • The casing, the impeller and the front panel are made of high-quality and durable UV-resistant plastic.
  • The specially designed aerodynamic profile of the mixed-flow impeller provides high air capacity and pressure combined with low-noise operation.
  • The fan is equipped with a specially designed backdraft damper to prevent back flow and heat losses during the fan standby.
  • The fan exhaust spigot incorporates specially designed air rectifiers to reduce air turbulence, noise level and boost air pressure.
MOTOR
  • Reliable motor with low energy demand.
  • Rated for continuous operation and is completely maintenance-free.
  • Integrated overheating protection.
CONTROL

Automatic control:

  • Control with the electronic control unit BU-1-60. The control unit is supplied separately.
  • Control with the turn-off delay timer T. The built-in turn-off delay timer enables operation of the fan within 2 up to 30 minutes after turning the fan off with a switch.
  • Control with the timer T1. After turning of the external switch the turn-on delay timer is activated for 10 seconds up to 2 minutes. The fan remains turned off. After the fan is turned off with the external switch the fan keeps running within 2 up to 30 minutes according to the settings of the turn-off delay timer.
  • Control with the timer and humidity sensor TH. If the indoor humidity exceeds the set humidity point adjustable from 60% to 90%, the fan switches automatically on and runs until the indoor humidity drops below the set humidity point. After that the fan continues running according to the timer settings and turns off.

Manual control:

  • Manual operation with a room light switch (not included in the delivery set).
  • Operation with a built-in pull cord switch V. Not applicable in case of the ceiling mounting.
MOUNTING FEATURES
  • Direct installation inside a ventilation shaft.
  • Flexible air ducts may be used in case of remote location of the ventilation shaft. The air duct is connected to the exhaust spigot with a fixing clamp.
  • Wall mounting with screws.
  • Suitable for ceiling mounting.
MOUNTING EXAMPLE
Modifications
Backdraft damper
Ball bearing motor
Pull-cord switch
Timer
Humidity sensor
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
Capacity diagram
Capacity diagram
  • Selection method:
  • Air flow:
  • Pressure:
Operating point
  • Air flow: --
  • Pressure: ---
Downloads
Downloads
Select document type
  • Advertising and printing products
  • Certificates
  • Technical documentation
Name
"VENTS Solid (One), VENTS Wave (One), VENTS Flip (One)" user's manual 11-2023 (V160EN-07) (pdf 1.77Mb)
"VENTS Flip" product description 01-2018 (pdf 4.04Mb)
Download high quality image "VENTS Flip" (psd 1.83Mb)
Download image "VENTS Flip" for your website (png 355.74Kb)
Certificates
Certificates
<p>
	Mark of conformity to the European Quality Standards and Electrical Safety issued by Association for Technical Inspection (Technischer Überwachungsverein, Germany).</p>

Mark of conformity to the European Quality Standards and Electrical Safety issued by Association for Technical Inspection (Technischer Überwachungsverein, Germany).

<p>
	Mark of conformity to the Polish Quality Standards and electrical safety issued by PCBC (Polish center for testing and certification). </p>

Mark of conformity to the Polish Quality Standards and electrical safety issued by PCBC (Polish center for testing and certification).

<p>
	Mark of conformity to the Slovak Quality Standards and electrical safety issued by EVPU (Slovakia).</p>

Mark of conformity to the Slovak Quality Standards and electrical safety issued by EVPU (Slovakia).

<p>
	Mark of conformity to the Ukrainian Quality Standards and electrical safety issued by UkrTEST.</p>

Mark of conformity to the Ukrainian Quality Standards and electrical safety issued by UkrTEST.

<p>
	Mark of conformity of the goods subject to obligatory certification in DSTR system as well as technical norms and standards acting in Russian Federation. Confirmed by the RosTEST certificates (Moscow). </p>

Mark of conformity of the goods subject to obligatory certification in DSTR system as well as technical norms and standards acting in Russian Federation. Confirmed by the RosTEST certificates (Moscow).

<p>
	Insulation class: double insulation.</p>

Insulation class: double insulation.

<p>
	Equipment protection rating.</p>

Equipment protection rating.

Legend
Legend
PICTURE SYMBOL DESIGNATION MODIFICATION DESCRIPTION
Flip L Modification with a ball bearing motor for long service life (around 40 000 operating hours). Installation at any angle is possible. The ball bearings require no maintenance and are greased for the entire service life.
Flip T Modification with a regulated turn-on delay timer.
Flip T1 Modification with a turn-on delay timer regulated from 10 seconds to 2 minutes and a turn-off delay timer regulated from 2 up to 30 minutes.
Flip TH Modification with a turn-off delay timer regulated from 2 up to 30 minutes and a humidity sensor regulated from 60% up to 90%.
Flip V Modification with a pull-cord switch.
Flip VT Modification with a pull-cord switch and a turn-off delay timer regulated from 2 up to 30 minutes.
Flip VTH Modification with a pull cord switch, turn-off delay timer regulated from 2 up to 30 minutes and a humidity sensor regulated from 60% up to 90%.
Video
Video

AccessoriesSimilar products
Share your opinion

Questionnaire
How often do you use equipment selection program?