Login

Privacy Policy (GDPR)
Authorization
Not registered yet? Take advantages of registration:
Products saving in a binding to the projects
Product consultation from our experts - Online
Registration
Signup
By using this form, you confirm that you have read the site terms of use Terms of use and completely accept the terms of use
Print version
Search results
Selected products
Mode PowerCurrentVoltagePower consumptionCurrentMaximum air capacity RPMSound pressure level at 3 m distanceMaximum transported air temperatureProtection ratingWeightASound pressure level at 3 m distanceElectric heater powerRPMNoise level at 3 mSpigot sizePhaseNumber of polesSound- and heat-insulated casing Frequency Minimum air capacityCurrentPowerPowerRPMAir capacityIP CodeVoltageElectric heater currentTotal unit powerTotal unit currentMaximum air capacity RPMConnected air duct sizeWeightPhaseFilter: extractFilter: supplyPressureWeight FrequencyH2 (air curtain without heating)H2 (air curtain with water heating)H2 (air curtain with electric heater)Fan powerFan currentAir capacityPhaseVoltageElectric heater powerElectric heater currentFan typeFilter typeType of water heaterType of electric heaterCurrent Air passMaterialAdjustmentEngine TypeSteel thicknessMaximum unit powerMax. unit power without electric heaterMax. unit current without electric heaterMaximum unit currentAir reach distanceProtection ratingFlow areaWeightRange of air streamInfluence areaSEC ClassPowerSEC ClassSEC ClassMotor protection ratingDuct diameterHeatingEC motorFormWidthHeightCasing materialOutdoor mountingSound-insulated casingDuctConnection diameterDesignTypeMountingSmoke removalMaximum air capacityCurrentMax. transported air temperatureMaximum transported air temperatureSound pressure level at 3 m distanceInsulationHeat recovery efficiencyHeat exchanger typeHeat exchanger materialLow-powered motorHigh-power versionBackdraft damperSound- and heat-insulated casing Low-powered motorTransported air temperatureAir capacityHeat recovery efficiencyMaximum fan powerFan currentMax. power of electric heaterMax. unit current of electric heaterWeightTurbine protection rating*
50 Hz - 0.76 - - - - - 48 - IP X4 - - - - - - - - - - - - - - 173 - - - 230 - - - 930 2125 - 4.3 1 - - - - 50 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - B - - 200 - no - 354 340 plastic no no for round air ducts - centrifugal exhaust , supply Inline - - - - - - - - - - - - - - - - - - - - - - - - To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor).
60 Hz - 0.94 - - - - - 49 - IP X4 - - - - - - - - - - - - - - 216 - - - 230 - - - 1020 2155 - 4.3 1 - - - - 60 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 200 - no - 354 340 plastic no no for round air ducts - centrifugal exhaust , supply Inline - - - - - - - - - - - - - - - - - - - - - - - - To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor).
- - - 230 - - 520 - 64 55 IP X4 4.5 - - - - - 150 - - - 60 - - - - - - - - - - - - - - - - - - 456.3 - - - - - - - - - - - - - - - - - - - - 220V / 60Hz - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
50 Hz 440 - - - - - - - - - - 1.23 - - 978 52 - - 6 - - - - - - - - IP X4 400 - - - - - - 52 3 - - - - 50 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - IP54 - - no - - - - yes no - - centrifugal exhaust for roof - - - - - - - - - - - - - - - -25 ... +60 6000 - - - - - - - -
60 Hz 599 - - - - - - - - - - 1.32 - - 1125 54 - - 6 - - - - - - - - IP X4 400 - - - - - - 52 3 - - - - 60 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - IP54 - - no - - - - yes no - - centrifugal exhaust for roof - - - - - - - - - - - - - - - -25 ... +60 6122 - - - - - - - -
- - - 230 1240 - - 1210 59 - IP X4 35 - - - - - - 1 4 - 50 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 600 300 galvanized steel - - for rectangular air ducts - centrifugal - Inline - - 6.45 - - - - - - - - - - no - -25 ... +50 2950 - - - - - - - -
50 Hz 184 - - - - - - - - - - 0.81 - - 2480 54 - - 2 - - - - - - - - IP X4 230 - - - - - - 9 1 - - - - 50 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - IP44 - - no - - - - yes no - - centrifugal exhaust for roof - - - - - - - - - - - - - - - -25 ... +50 1450 - - - - - - - -
60 Hz 232 - - - - - - - - - - 0.90 - - 2320 53 - - 2 - - - - - - - - IP X4 230 - - - - - - 9 1 - - - - 60 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - IP44 - - no - - - - yes no - - centrifugal exhaust for roof - - - - - - - - - - - - - - - -25 ... +50 1320 - - - - - - - -
- - - 230 183 - 1820 2780 49 - IP X4 9.4 - - - - - - 1 - - 50/60 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 315 - yes - - - polymer coated steel yes - for round air ducts - centrifugal supply and exhaust outdoor mounting , Inline - - 1.44 -25 +60 - - - - - - yes no - - - - - - - - - - - - To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor).
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 0.76 50.2 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
50 Hz - - 230 510 - - 1415 51 - IP X4 36.38 - - - - - - 3 4 - 50 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 600 350 galvanized steel - - for rectangular air ducts - centrifugal - Inline - - 1.41 - - - - - - - - - - - - -40 … +60 2970 - - - - - - - -
60 Hz - - 230 750 - - 1610 53 - IP X4 36.38 - - - - - - 3 4 - 60 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 600 350 galvanized steel - - for rectangular air ducts - centrifugal - Inline - - 1.44 - - - - - - - - - - - - -40 … +60 3410 - - - - - - - -
- - - 220-240 205 1000 - 49 -25 +50 IP X4 7.7 - - - - - 200 1 - - 50/60 - - - - - - - - - - - - - - - - - - 0 - - - - - - - - - - - - - - - - - - - - 220В / 50Гц - - - - - - - - - - - B - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
50 Hz - - 1~230 112 - 485 2465 52 - IP X4 6.5 - - - - - - - - - 50 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - C - - - - 150 - - - - - galvanized steel , ABS plastic - - for round air ducts - centrifugal ceiling mounting - - 0.5 -25 +50 - - - - - - - - yes - no - - - - - - - - - -
60 Hz - - 1~230 136 - 531 2550 53 - IP X4 6.5 - - - - - - - - - 60 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - C - - - - 150 - - - - - galvanized steel , ABS plastic - - for round air ducts - centrifugal ceiling mounting - - 0.6 -25 +50 - - - - - - - - yes - no - - - - - - - - - -
- - - 400 282 - - 1300 52 - IP X4 17.5 - - - - - - 3 4 - 50 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 400 200 galvanized steel - - for rectangular air ducts - centrifugal - Inline - - 0.60 - - - - - - - - - - no - -25 ... +45 1470 - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 12,7 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 150 - - - - - polymer coated steel - - - - - - wall mounting , ceiling mounting - - - - - - - - - - - - - - - - - - - - - - - - -
Min speed - - 1~230 - - 1846 - 38 - IP X4 - - - - - - - - - - 60 - - - - 1000 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 0.73 - - - - - - - - - - - - - - - - 146 - - IP 20 400 - - - - - polymer - - for round air ducts - mixed-flow - Inline - 513 - -25...+55 - - - - - - - - - - - - - - - - - - - - -
Mid speed - - 1~230 - - 2401 - 42 - IP X4 - - - - - - - - - - 60 - - - - 1320 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1.00 - - - - - - - - - - - - - - - - 208 - - IP 20 400 - - - - - polymer - - for round air ducts - mixed-flow - Inline - 667 - -25...+55 - - - - - - - - - - - - - - - - - - - - -
Max speed - - 1~230 - - 3390 - 43 - IP X4 - - - - - - - - - - 60 - - - - 1566 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1.40 - - - - - - - - - - - - - - - - 300 - - IP 20 400 - - - - - polymer - - for round air ducts - mixed-flow - Inline - 942 - -25...+55 - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - 150 5.2 1200 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - electric reheating - - - - - - - for round air ducts 200 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - 380-480 - - - - 63 - - 46 - - - 1560 - - 3 - - 50/60 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3.27 - - - - - - - - - - IPX4 - - - - - 1323 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -20 … +60 8110 - - - - - - IP54 -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 0.048 6.8 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - 230 244 - - 910 37 - IP X4 40.5 - - - - - - 1 6 - 50 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 500 250 galvanized steel - - for rectangular air ducts - centrifugal - Inline - - 1.22 - - - - - - - - - - yes - -20 … +50 1460 - - - - - - - -
50 Hz 184 - - - - - - - - - - 0.89 - - 945 47 - - 6 - - - - - - - - IP X4 230 - - - - - - 32.7 1 - - - - 50 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - IP54 - - no - - - - yes no - - centrifugal exhaust for roof - - - - - - - - - - - - - - - -30 … +60 2740 - - - - - - - -
60 Hz 249 - - - - - - - - - - 1.10 - - 1071 49 - - 6 - - - - - - - - IP X4 230 - - - - - - 32.7 1 - - - - 60 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - IP54 - - no - - - - yes no - - centrifugal exhaust for roof - - - - - - - - - - - - - - - -30 … +60 3289 - - - - - - - -
- - - - - - - - - - - - - 65 18000 - - - - - - - - - - - - - - 400 26 19300 31.7 - 1150 315 96 3 G4 G4 - - 50/60 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - electric heating - - - - aluzinc - - - - - supply and exhaust with heat recovery floor mounting - - - - -25...+40 - 50 mm mineral wool - cross-flow polystyrene - - - - - - 2200 up to 77 2 pcs. x 650 2 pcs. x 2.84 - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 0.032 13.3 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4.7 - - - - - - - 250 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - 160 7.4 1700 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - electric heating - - - - - - - for round air ducts 160 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - 230 82 - 360 - 56 25 +55 IP X4 3.2 - - - - - 125 - - - 60 - - - - - - - - - - - - - - - - - - 425 - - - - - - - - - - - - - - - - - - - - 220V / 60Hz - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - 1~230 910 - 6200 1330 64 - IP X4 - - - - - - - 1 4 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 450 - - - - - polymer coated steel - - - - - Inline - - 4.4 -25 +60 - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 0.007 - nonadjustable - 0.8 - - - - - - - - - - - - - - - - - - round - - - - - - 100 - - - - - - - - - - - - - - - - - - - - - - - - - 6.1 - -
- - - - - - - - - - - - - - - - - - - - - - 180 5.2 1200 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - electric preheating - - - - - - - for round air ducts 250 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - 230 140 - 1380 53 60 IP X4 17 - - - - - - 1 - 1 50 - - - - - 2500 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 220В / 50Гц - - - - - 10 - - - 10-13 78-133 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - 230 76 - 350 - 52 25 +50 IP X4 4.5 - - - - - 125 - - - 60 - - - - - - - - - - - - - - - - - - 473.8 - - - - - - - - - - - - - - - - - - - - 220V / 60Hz - - - - - - - - - - - B - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
50 Hz - 0.47 - - - - - 46 - IP X4 - - - - - - - - - - - - - - 107 - - - 230 - - - 780 2660 - 3 1 - - - - 50 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - B - - 200 - no - 354 340 plastic no no for round air ducts - centrifugal exhaust , supply Inline - - - - - - - - - - - - - - - - - - - - - - - - To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor).
60 Hz - 0.58 - - - - - 46 - IP X4 - - - - - - - - - - - - - - 132 - - - 230 - - - 890 2765 - 3 1 - - - - 60 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 200 - no - 354 340 plastic no no for round air ducts - centrifugal exhaust , supply Inline - - - - - - - - - - - - - - - - - - - - - - - - To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor).
- - - 120 - - 404 - 57 - - - - - - - - 100 - - - 60 - - - - - - - - - - - - - - - - - - 410.6 - - - - - - - - - - - - - - - - - - - - 120В / 60Гц - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- 755 - - - - - - - - - - 1.50 - - 1440 57 - - 4 - - - - - - - - IP X4 400 - - - - - - 41 3 - - - - 50 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - IP54 - - no - - - - yes no - - centrifugal exhaust for roof - - - - - - - - - - - - - - - -30 … +50 5920 - - - - - - - -
- - - 400 2460 - - 1300 60 - IP X4 49.5 - - - - - - 3 4 - 50 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 600 350 galvanized steel - - for rectangular air ducts - centrifugal - Inline - - 3.93 - - - - - - - - - - no - -20 … +40 5020 - - - - - - - -
50 Hz 108 - - - - - - - - - - 0.49 - - 2580 50 - - 2 - - - - - - - - IP X4 230 - - - - - - 7 1 - - - - 50 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - C IP44 - - no - - - - yes no - - centrifugal exhaust for roof - - - - - - - - - - - - - - - -25 ... +50 880 - - - - - - - -
60 Hz 118 - - - - - - - - - - 0.54 - - 2840 51 - - 2 - - - - - - - - IP X4 230 - - - - - - 7 1 - - - - 60 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - IP44 - - no - - - - yes no - - centrifugal exhaust for roof - - - - - - - - - - - - - - - -25 ... +50 883 - - - - - - - -
- - - 230 164 - - 2900 48 - IP X4 7.3 - - - - - - 1 - - 50/60 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 315 - yes - - - polymer coated steel yes - for round air ducts - centrifugal supply and exhaust outdoor mounting , Inline - - 1.15 -25 +60 - - - - - - no no - - - - 1370 - - - - - - - To meet the requirements of ErP 2018, a speed controller and local demand control typology must be applied (connect a sensor).
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 0.448 34.7 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - 400 1508 - - 1440 58 - IP X4 54 - - - - - - 3 4 - 50 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 800 500 galvanized steel - - for rectangular air ducts - centrifugal supply and exhaust Inline - - 2.71 - - - - - - - - - - - - -30 … +60 7800 - - - - - - - -
- - - 230 104 563 - 60 25 +55 IP X4 7.2 - - - - - 150 - - - 60 - - - - - - - - - - - - - - - - - - 481.3 - - - - - - - - - - - - - - - - - - - - 220V / 60Hz - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - 6000 - - - - - - - - - - - - - - - 1300 1500 2050 3630 6 6000 3 400 36000 52

VKPF 4D 700х400

FB 700х400

NK 700х400-36,0-3

- - - - - - - - - - - - - - - - - - - - - - without heating - - 700 400 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - 230 283 - - 890 47 - IP X4 33 - - - - - - 1 6 - 50 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 500 300 galvanized steel - - for rectangular air ducts - centrifugal - Inline - - 1.59 - - - - - - - - - - no - -20 … +70 1550 - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - 230 - - - - 3280 160 82 1 G4 G4 , F7 - - 50/60 - - - - - - - - - - - - - - - - - - - - 1600 200 1.4 7.5 - - - - - - - - A - - - - - - - - painted steel - - - - - - - - - - - - 33 40 mm mineral wool 76...85 rotary aluminium - - - - - -25 ... +40 440 - - - 1400 6.1 - - -
Min speed - - 1~230 - - 2090 1350 38 - IP X4 - - - - - - - - - - 50 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 0.60 - - - - - - - - - - - - - - - - 126 - - IP 20 355 - - - - - polymer - - for round air ducts - mixed-flow - Inline - 581 - -25...+55 - - - - - - - - - - - - - - - - - - - - -
Mid speed - - 1~230 - - 2296 1400 38 - IP X4 - - - - - - - - - - 50 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 0.58 - - - - - - - - - - - - - - - - 131 - - IP 20 355 - - - - - polymer - - for round air ducts - mixed-flow - Inline - 638 - -25...+55 - - - - - - - - - - - - - - - - - - - - -
Max speed - - 1~230 - - 2485 1470 43 - IP X4 - - - - - - - - - - 50 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 0.66 - - - - - - - - - - - - - - - - 150 - - IP 20 355 - - - - - polymer - - for round air ducts - mixed-flow - Inline - 690 - -25...+55 - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - 150 5.2 1200 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - electric reheating - - - - - - - for round air ducts 160 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - 200-277 - - - - 58 - - 27 - - - 1450 - - 1 - - 50/60 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3.90 - - - - - - - - - - IPX4 - - - - - 526 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -25 ... +50 5380 - - - - - - IP54 -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 0.032 5.7 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - 230 720 - - 820 43 - IP X4 72 - - - - - - 1 6 - 50 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 600 350 galvanized steel - - for rectangular air ducts - centrifugal - Inline - - 3.6 - - - - - - - - - - yes - -20 … +60 2755 - - - - - - - -
- 48 - - - - - - - - - - 0.23 - - 1440 46 - - 4 - - - - - - - - IP X4 230 - - - - - - 12.1 1 - - - - 50 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - B IP44 - - no - - - - yes no - - centrifugal exhaust for roof - - - - - - - - - - - - - - - -25 ... +50 820 - - - - - - - -
- - - - - - - - - - - - - 48 9000 - - - - - - - - - - - - - - 400 13 9490 15.16 - 1650 250 85 3 G4 G4 - - 50/60 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - E - - - electric heating - - - - aluzinc - - - - - supply and exhaust with heat recovery floor mounting - - - - -25...+40 - 50 mm mineral wool - cross-flow polystyrene - - - - - - 800 up to 78 2 pcs. x 245 2 pcs. x 1.08 - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 0.216 29.7 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3.5 - - - - - - - 160 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - 80 3.5 800 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - electric heating - - - - - - - for round air ducts 125 - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Share your opinion

Questionnaire
Basic parameter for domestic fan selection